INSTALLATION INSTRUCTIONS
GENERAL
This fan system may be supplied in kit form and installed in accordance with these instructions OR it may have been factory fitted.
PACKING LIST
• Riva Plus Fan Kit
TOOLS REQUIRED
• 10mm A/F Spanner
Power supply
A 230v 50 - 60Hz supply is required.
THIS APPLIANCE MUST BE EARTHED
Provision for the power supply should be made before installing the product, with connections made by a qualified electrician via a 3 Amp supply and complying with any local and national regulations and guidelines
•The appliance must be protect by a 3 amp fuse
•The electrical connection must allow for disconnection
•Use heat resistant cable
If the electricity supply cable is damaged do not use the appliance until it has been replaced. For safety reasons the replacement should be carried out by a Stovax servicing agent or a similarly competent electrician.
Live | Brown | Terminal Marked L / coloured RED | |
wire |
|
|
|
|
|
| |
Neutral | Blue | Terminal Marked N / coloured | |
wire |
| BLACK |
|
Earth | Green and | Marked E / | / colour GREEN or |
wire | yellow stripes | GREEN & YELLOW |
230v 50 - 60Hz supply is required
WARNING – FAILURE TO CONNECT THE WIRES CORRECTLY COULD PUT PEOPLE AT RISK FROM ELECTRIC SHOCK OR FIRE.
INSTALLATION
1
Velcro Pads
PR8179
M6 Screws
PR8178
1.1• Position Fan kit as shown, diagram 1
•Attach using M6 Nuts supplied
•Secure control box in a convenient place using the self adhesive Velcro pads supplied
Commissioning
1
|
| 3 way switch |
| |
Speed control | PR8179 | |||
|
1.Check operation of fan kit
2.Explain the use of all the controls to the customer
3.Store these instructions with the ones supplied with the cassette
3