INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

GENERAL

This fan system may be supplied in kit form and installed in accordance with these instructions OR it may have been factory fitted.

PACKING LIST

• Riva Plus Fan Kit

TOOLS REQUIRED

• 10mm A/F Spanner

Power supply

A 230v 50 - 60Hz supply is required.

THIS APPLIANCE MUST BE EARTHED

Provision for the power supply should be made before installing the product, with connections made by a qualified electrician via a 3 Amp supply and complying with any local and national regulations and guidelines

The appliance must be protect by a 3 amp fuse

The electrical connection must allow for disconnection

Use heat resistant cable

If the electricity supply cable is damaged do not use the appliance until it has been replaced. For safety reasons the replacement should be carried out by a Stovax servicing agent or a similarly competent electrician.

Live

Brown

Terminal Marked L / coloured RED

wire

 

 

 

 

 

 

Neutral

Blue

Terminal Marked N / coloured

wire

 

BLACK

 

Earth

Green and

Marked E /

/ colour GREEN or

wire

yellow stripes

GREEN & YELLOW

230v 50 - 60Hz supply is required

WARNING – FAILURE TO CONNECT THE WIRES CORRECTLY COULD PUT PEOPLE AT RISK FROM ELECTRIC SHOCK OR FIRE.

INSTALLATION

1

Velcro Pads

PR8179

M6 Screws

PR8178

1.1• Position Fan kit as shown, diagram 1

Attach using M6 Nuts supplied

Secure control box in a convenient place using the self adhesive Velcro pads supplied

Commissioning

1

 

 

3 way switch

 

Speed control

PR8179

 

1.Check operation of fan kit

2.Explain the use of all the controls to the customer

3.Store these instructions with the ones supplied with the cassette