Opening Dimensions

UNDERCOUNTER REFRIGERATION

Opening Dimensions

UNDERCOUNTER MODELS

24" (610)

OPENING

DEPTH

TOP VIEW

Electrical

The electrical supply should be located within the shaded area shown in the illustration. For ice machine models, it is recommended that electrical supply be placed in an adja- cent cabinet. A separate circuit, servicing only this appli- ance is required.

IMPORTANT NOTE: For outdoor models UC-24RO and UC-15I(P)O, a ground fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock. A GFCI is not recommended for use with other undercounter models and may cause interruption of operation.

341/2"

(876)

OPENING

HEIGHT

SIDE VIEW

W

OPENING WIDTH

FRONT VIEW

Installation must comply with all applicable electrical codes.

ELECTRICAL REQUIREMENTS

 

Electrical Supply

115 VAC, 60 Hz

Service

15 amp

Receptacle

3-prong grounding-type

LEFT SIDE

OF OPENING

OPENING WIDTH

MODEL

W

UC-24R

24" (610)

UC-24C(I)

24" (610)

UC-24BG

24" (610)

UC-24RO

24" (610)

ICE MACHINE

W

UC-15I(P)

151/4" (387)

UC-15I(P)O

151/4" (387)

2"

151/2"

(51)

(394)

 

3" (76)

 

FLOOR

Electrical supply location.