OPERATING INSTRUCTIONS

 

 

SEAR STATIONBURNER LIGHTING

Summary lighting instructions are inside the left hand cabinet door.

DANGER

Failure to open the lid while igniting the barbecue’s burners, or not waiting 5 minutes to allow the gas to clear if the barbecue does not light, may result in an explosive flame-up which can cause serious bodily injury or death.

The Sear Stationburner has an on or off control setting. To ignite the Sear Stationburner you must first ignite the two adjacent main burners.

ADJACENT MAIN BURNER SNAP IGNITION

Note: Each main burner control knob snap igniter creates a spark from the igniter electrode to the burner lighting tube.You generate the energy for the spark by pushing in the control knob and turning to“START/HI”.This will ignite each individual burner.

WARNING: Check hose before each use of barbecue for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the barbecue. Replace using only Weber® authorized replacement hose. Contact the Customer Service Representative in your area using the contact information on our web site.

Log onto www.weber.com®.

1)Open the lid.

2)Make sure all burner control knobs are turned off. (Push control knob in and turn clockwise to ensure that it is in the “OFF” position.)

3)Turn on the gas supply at source.

WARNING: Do not lean over the open barbecue.

4)Ignite each adjacent Sear Stationmain burner. Push the control knob in and turn to “START/HI” until you hear the igniter snap - continue to hold control knob in for two seconds. This action will spark the igniter, the burner lighting tube and then main burner.

5)Check that the burner is lit by looking through the cooking grates. You should see a flame. If burner does not light on first try, push control knob in and turn to OFF. Repeat lighting procedure a second time.

To ignite the Sear Stationburner continue with Step 6.

Sear Burner Lighting: Ignition by an adjacent ignited Main Burner.

6)Turn -Sear Stationburner control knob to the ON position.

7)Verify burner ignition by visual inspection of a flame.

WARNING: If ignition does not occur in 5 seconds, turn burner control OFF, wait 5 minutes, and repeat steps 6 & 7, or see Match Lighting instructions.

WARNING: If the burner still does not light, turn the burner control knob to “OFF” and wait 5 minutes to let the gas clear before you try again or try to light with a match.

Note: See Maintenance for burner removal and cleaning procedure.

ARRÊTÉ

EN MARCHE

OFF

ON

APAGADO

ENCENDIDO

B

A

B.

A.

OFF

ON

1

5

7

2

4

6

* The grill illustrated may have slight

3

 

differences than the model purchased.

 

26

EN MARCHE

ON

ENCENDIDO

TO EXTINGUISH

Push in and turn each burner control knob clockwise to “OFF” position. Turn gas supply off at the source.