US/Canada 1-Pump Cayman Model (60Hz)
240V/50A*240V/30A**
Voltage: 240VAC 240 VAC
# of Wires: 3 3
Frequency: 60Hz 60Hz
Current Draw: 34A 24A
Circuit Breaker: 50A, 2-Pole 30A, 2-Pole
*In the 50A configuration, the heater will operateat the same time as the
high-speed jets pump. This is the factory setting.
** In the 30A configuration, the heater will not operateat the same time as
the high-speed jets pump.
US/Canada Lagunas Convertible Models (60Hz)
120V/15A* 240V/30A* 240V/40A**
Voltage: 120 VAC 240 VAC 240 VAC
# of Wires: 3 (15A GFCI Cord) 4 4
Frequency: 60Hz 60Hz 60Hz
Current Draw: 12A 21A 30A
Circuit Breaker: 15A, 1-Pole 30A, 2-Pole 40A, 2-Pole
For 240 VAC Heater Operation: Move the red wire on the main terminal strip
(TB1) from position #1 to position #3. Make certain wires are connected exactly
as shown in Figure-D (Page 12) before applying power. Failure to do so will
result in damage to the circuit board and/or related components and void the
manufacturer’s warranty.
*In the 15A and 30A configuration, the heater will not operate at the same
time as the high-speed jets pump. The factory setting is 120V/15A.
** If the spa is to be operated on 40A service, remove the jumper JP1 #1-2 on
the circuit board to allow the heater to operate at the same time as the
high-speed jets pump (Page 32).
5.0 Power Requirements