Export 1-Pump Cayman / Lagunas Models (50Hz)
230V/20A*230V/30A**
Voltage: 230 VAC 230 VAC
# of Wires: 3 3
Frequency: 50Hz 50Hz
Current Draw: 15A 21A
Circuit Breaker: 20A 30A
*In the 20A configuration, the heater will not operateat the same time as
the main jets pump. This is the factory setting.
** In the 30A configuration, the heater will operateat the same time as
the main jets pump.
Export 2-Pump Palermo / Bahia Models (50Hz)230V/20A* 230V/30A** 230V/40A***
Voltage: 230 VAC 230 VAC 230 VAC
# of Wires: 3 3 3
Frequency: 50Hz 50Hz 50Hz
Current Draw: 15A 23A 29A
Circuit Breaker: 20A 30A 40A
*In 20A configuration, the heater will not operatewhile either jets pump
is running in high speed. This is the factory setting.Note: pump 2
runs only in high speed.
** In 30A configuration, the heater will not operatewhile both jets pumps
are running in high speed. Note: pump 2 runs only in high speed.
*** In 40A configuration, the heater will operatewhile either jets pump
is running in high speed. Note: pump 2 runs only in high speed.
US/Canada 2-Pump Palermo / Bahia Models (60Hz)240V/50A* 240V/30A** 240V/60A***
Voltage: 240 VAC 240 VAC 240 VAC
# of Wires: 3 3 3
Frequency: 60Hz 60Hz 60Hz
Current Draw: 36A 24A 43A
Circuit Breaker: 50A, 2-Pole 30A, 2-Pole 60A, 2-Pole
*In 50A configuration, the heater will not operatewhile both jets pumps
are running in high speed. Note: pump 2 runs only in high speed. This is
the factory setting.
** In 30A configuration, the heater will not operatewhile either jets pump
is running in high speed. Note: pump 2 runs only in high speed.
*** in 60A configuration, the heater will operatewhile both jets pumps are
running in high speed. Note: pump 2 runs only in high speed.