Page 39
JP9-5 JP9-7 JP9-9 JP9-11 Circ. Pump Pump Blower Light With Factory
Pump 1 2 Power Supply 1 Heater Power Supply 1+2 Setting
0000ON ON ON ON 12.1 Amp (2.9kW) X 23.6 Amp (5.6kW)
0001ON ON ON ON 12.1 Amp (2.9kW) 12.1 Amp (2.9kW)
0010ON ON ON ON 12.1 Amp (2.9kW) X 23.6 Amp (5.6kW)
0011ON ON ON ON 16.6 Amp (3.9kW) 16.6 Amp (3.9kW) A
0100ON ON ON ON 12.1 Amp (2.9kW) X 23.6 Amp (5.6kW) B
0101ON ON ON ON 12.1 Amp (2.9kW) 12.1 Amp (2.9kW)
0110ON ON ON ON 12.1 Amp (2.9kW) X 23.6 Amp (5.6kW)
0111ON ON ON ON ON 20.1 Amp* (4.8kW) 20.1 Amp (4.8kW) *
1000ON ON ON ON 12.1 Amp (2.9kW) X 23.6 Amp (5.6kW)
1001ON ON ON ON 12.1 Amp (2.9kW) 12.1 Amp (2.9kW)
1010ON ON ON ON 16.6 Amp (3.9kW) X 28.1 Amp (6.7kW)
1011ON ON ON ON 16.6 Amp (3.9kW) 16.6 Amp (3.9kW)
1100ON ON ON ON 12.1 Amp (2.9kW) X 23.6 Amp (5.6kW)
1101ON ON ON ON 12.1 Amp (2.9kW) 12.1 Amp (2.9kW)
1110ON ON ON ON ON 20.1 Amp* (4.8kW) X 31.6 Amp (7.6kW) *
1111ON ON ON ON ON 20.1 Amp* (4.8kW) 20.1 Amp (4.8kW) *
Chart Symbol Legend
0 = Jumper Off Pump 1 = 8 Amp, * The system fuse and fuse holder (F1) on these models must be changed to
1 = Jumper On Pump 2 = 8 Amps 25 Amps to accommodate the higher current draw from these models.
ON = Device On Circulation Pump = 0.5 Amps,
Blower = 3.5 Amps
A = Factory Setting for Cameo, Optima, Marin and Altamar
Light = 0.1 Amps
B = Factory Setting for Capri
Circuit Board Jumpers (See Diagram, Page 40) Total Current Draw
15.0 Jumper Configurations / Max CurrentChartENGLISH