HEARTH PRODUCTS

KITS AND ACCESSORIES

750,195M

CHARCOAL CANOPY HOOD KITS
Rev. NC, 03/2006

 

INSTALLATION INSTRUCTIONS FOR CANOPY HOOD KITS

FOR USE WITH UVF-36, UVFRC-3628, UVFRC-3628-H

UVFRC-4228 & UVFRC-4228-H UNIVERSAL VENTFREE FIREBOXES

KIT CONTENTS:
1 ea. Charcoal Canopy Hood
3 ea. Screws
1 ea. Instruction Sheet
Charcoal Canopy Hood Kits
CAT. NO.

MODEL NO.

WHERE USED

 

 

 

H1989

FC36

UVF-36, UVFRC-3628,
UVFRC-3628-H(UVF-36 standard part)

 

 

 

 

 

H1990

FC42

UVFRC-4228 & UVFRC-4228-H

 

 

 

Table 1
GENERAL INFORMATION

These canopy hood kits are design to be fitted to the face of the appliance directly above the firebox opening. In addition to providing an aesthetically pleasing appearance to your appliance installation, the canopy reduces heat effects to decorative mantels and finish materials located directly above the fireplace and reduces the Mantel / Trim clearances (see Figure 4 in the Installation and Operation Manual).

NOTE: A canopy hood is a standard part for model UVF-36. This model requires a canopy hood on all installations.

The manufacturer recommends that the installation and Operation Manual provided with the appliance be read completely and understood thoroughly before proceeding with the installation of these kits. ALL WARNINGS AND

PRECAUTIONS IN THAT DOCUMENT APPLY TO THESE INSTRUCTIONS.
TOOLS NEEDED:
5/16" Nut Driver or Socket
INSTALL ONLY WHEN APPLIANCE IS OFF AND COLD!

Removing Screens & Rods: Remove screws (see dotted lines). Pull out rods from locating holes on side of firebox opening.

Reinstalling Screens & Rods: Insert rods into corresponding locating holes on sides of firebox opening, then reinstall screws as shown.

INSTALLATION INSTRUCTIONS

The factory-supplied canopy must be installed on the firebox for safe operation for model UVF-36 (this part is optional for other models). Step 1. Remove screen and rod assemblies as shown in Figure 1. Step 2. Align the canopy with the holes in the side frames.

Step 3. Install three screws as shown in Figure 2. Step 4. Make sure canopy is level and secure.

Step 5. Reinstall screen and rod assemblies (see Figure 1)
Canopy

Figure 1

Figure 2

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

LHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and the discontinuance of colors, styles and products. Consult your local distributor for fireplace code information.

Printed in U.S.A. © 2006 by LHP

 

LHP

 

1110 West Taft Avenue

P/N 750,195M REV. NC 03/2006