10
SUPERIOR® DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • CARE AND OPERATION INSTRUCTIONS

MAINTENANCE

(See Maintenance Schedule, Page 26)
Refer to the maintenance schedule for maintenance
tasks, procedures, periodicity and by whom they
should be performed. Always verify proper opera-
tion of the appliance after servicing.
Replacing Logs
If the logs become damaged by accident or
improper handling and need replacement,
use only the proper replacement logs from
manufacturer (see Pages 13,14 and 15 f or
ordering information).
Re-Install Embers and Logs
Carefully follow placement instructions on
Pages 12 through 15. All logs should fit
onto corresponding pins and/or log stop-
pers. This will ensure a proper flame and
safe combustion.
Inspect Wiring
Refer to wiring diagrams on Page 18.
CAUTION: When servicing controls, label
all wires prior to disconnection. Wiring
errors can cause improper and danger-
ous operation. Verify proper operation
after servicing.
ATTENTION: Au moment de l'entretien
des commandes, étiquetez tous les fils
avant de les débrancher. Des erreurs
de cáblage peuvent entraîner un fonc-
tionnement inadéquat et dangereux.
Inspect and clean all wire connections. Ensure
that there is no melting or damage. Inspection
should include:
Terminals at the Valve
OFF/ON Switch
(Optional Control Switch) Wall Thermostat,
Remote Control or Remote Wall Switch Kit
Inspect Burner Flame Appearance
Ensure that the burner flame appearance
resembles the flame shown in Figures 12, 13
and 14 and as described in Flame Appearance
and Sooting on Page 16. The Homeowner must
contact a qualified service technician at once if
any abnormal condition is observed.
Small Area Paint Touch-up
The finish of the appliance is a high-quality
powdercoat. Only use factory supplied
powdercoat pain t kit for touch -ups. Paint
is available at your local authorized Lennox
Hearth Products dealer. Never attempt to
paint a hot fireplace.
Do not attempt to repaint the appliance until
the finish is completely cured (see Burn-In
Period on Page 7). If the surface later becomes
stained or marred, it may be lightly sanded and
touched up with spray paint.
CAUTION: Wear gloves and safety
glasses for protection while doing
required maintenance.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adé-
quatement une fois l'entretien terminé.
Always turn off gas to the pilot (millivolt
appliances) before cleaning. Before re-
lighting, refer to the lighting instructions
in this manual. Instructions are also found
on a pull-out panel located in the control
compartment.
Before re-lighting the fireplace, refer to the
lighting instructions in this manual. Instruc-
tions are also found on pull-out panels
located below the glass door in the control
compartment.
Inspect Venting System
The appliance and venting system should be
thoroughly inspected before initial use and
at least annually by a qualified service techni-
cian (inspection should include ensuring that
exhaust or intake passages are unobstructed
and vent components are properly assembled
and not damaged). Homeowner must contact
a qualified service technician at once if any
abnormal condition is observed.
If the venting system is disassembled for any
reason, a qualified service technician should
follow vent installation instructions for proper
reassembly and proper sealing of the venting
system components. However, more frequent
periodic inspections and cleanings should be
performed by the homeowner.
Cleaning Glass
(Also see Front Glass Enclosure Panel, Removal
and Installation on Page 11).
Note: Clean glass after first two weeks of
operation (after Burn-In period is over) and
then only when necessary and only when the
fireplace is cool. Wipe surface with clean,
dampened, soft cloth. Follow with dry, soft
towel as desired. Take care not to scratch the
glass surface.
Clean the viewing glass periodically to remove
any build-up caused from the following:
IMPORTANT: Do not use abrasive clean-
ers on glass. Never clean the glass when
it is hot.
During start-up, it is normal for condensa-
tion to form on the inside of the glass (this
condensation and fog will usually disappear
in a few minutes). The moisture can cause
lint, dust and other airborne particles to cling
to the glass surface.
Initial curing of the high temperature paint
and burning off of lubricants used in the
manufacturing process may result in a film
on the glass.
A white coating may form on the glass as a
result of impurities and minerals in the fuel.
It is recommended that the glass be cleaned
two or three times during each heating season,
depending on the circumstances present. The
following cleaning solutions are approved for
use to clean glass:
• Non-ammonia based household cleaner
• 50%-50% mix of white vinegar and water
• Gas replace/stove glass cleaner
Inspect Glass Gasket
Visually inspect the gasket on the backside of
the glass enclosure panels. The gasket surface
must be clean, free of irregularities and seated
firmly.
Clean Control Compartment
Keep control compartment clean by vacuuming
or brushing at least twice a year. More frequent
cleaning may be required due to excessive lint
from carpeting, bedding materials, etc. It is
important that control compartments, burners
and circulating air passageways of the appli-
ance be kept clean.
Clean Logs And Burner
Carefully remove the logs (use care when han-
dling the fiber logs, as they become quite fragile
after curing). Vacuum out any foreign matter
(lint, carbon, etc.) on the burner. Ensure the
burner ports are “open.” Remove any carbon
deposits from the under side of the logs using
a vacuum cleaner, or a soft bristled brush (i.e.
paint brush).
Note: Improper positioning of logs can create
carbon build-up and will alter the performance
of the appliance.
WARNING
Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.