NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
37

Figure 65

Figure 66

BURNER POSITIONING
REAR BURNERFRONT BURNERPILOTBURNER

Note: The burners are not identical. Position them so

that the circular burner ports run as shown. Note

especially the vertical run of ports relative to the pilot

burner. Bracket A on the rear burner will interfere with

the pilot burner if an attempt is made to install the

rear burner in the front burner’s position.

BRACKET A BURNERPORTS
NOTE: INSTALL REAR BURNER FIRST,
THEN FRONT BURNER.
BURNER
ORIFICE
Step 10. Reassemble the remaining compo-
nents by reversing the procedures outlined in
the preceding steps.
Step 11. Attach the conversion label provided
in the conversion kit to the rating plate on the
appliance.
Step 12. Turn on gas supply and test for gas
leaks. See Test All Connections For Gas Leaks
on Page 28.
Step 13. Attach manometer to the manifold
side pressure test fitting and verify manifold
pressure reads 3.5 inches water column (0.87
kPa) for natural gas, and 10.0 inches water
column (2.49 kPa) for propane gas.
ALWAYS TEST PRESSURES WITH THE VALVE
REGULATOR CONTROL AT THE HIGHEST
SETTING.