35
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Natural Gas to Propane Gas
Conversion Kits
Fireplace
Type
Cat. No.
(model)
Millivolt
85L65
FGCK-DMOMNP
Electronic
85L79
FGCK-DMOENP
Propane Gas to Natural Gas
Conversion Kits
Fireplace
Type
Cat. No.
(model)
Millivolt
85L72
FGCK-DMOMPN
Electronic
85L86
FGCK-DMOEPN
INSTALLATION INSTRUCTIONS
Step 1. TURN OFF THE GAS SUPPLY TO THE
APPLIANCE and disconnect power supply at the
circuit breaker. Ensure appliance is cold.
CAUTION: THE GAS SUPPLY SHALL BE
SHUT OFF PRIOR TO DISCONNECTING THE
ELECTRICAL POWER, BEFORE PROCEEDING
WITH THE CONVERSION.
ATTENTION : AVANT D’EFFECTUER
LA CONVERSION, COUPEZ D’ABORD
L’ALIMENTATION EN GAZ, ENSUITE, COU-
PEZ L’ALIMENTATION éLECTRIQUE.
Step 2. Remove the front glass door assembly
from the appliance (see Removing Glass Enclo-
sure Panels on Page 30). Remove the control
compartment door (see Control Compartment
Door Removal on Page 27).
Step 3. Carefully remove the logs. Exercise
care so as not to break the logs.
Step 4. Refer to Figure 60.
Remove the front burner and then the rear
burner.
FRONT OF FIREPLACE
REAR BURNER
FRONT BURNER
VENTURI
TUBE ARM
VENTURI
TUBE ARM AIR SHUTTER
ADJUSTMENT LEVER
FIREBOX SUBFLOOR
NOTE: REMOVE FRONT BURNER FIRST,
THEN REAR BURNER.
Figure 60
Millivolt Appliances
Step 5. - SIT Systems - Refer to Figure 61
on Page 36 and the instructions provided with
the kit. Using a Torx T20 (with 1/4" shank and
center hole), tool or standard flat screwdriver
remove and discard the three pressure regulator
mounting screws. Remove the pressure regu-
lator, spring, poppet, diaphragm and bushing.
Discard all removed components.
Ensure the rubber gasket installed on the back of
the replacement pressure regulator is properly
positioned and install the new pressure regula-
tor using the new screws supplied with the kit.
Tighten screws to 25 In. lb. torque.
In Canada:
THE CONVERSION SHALL BE CAR-
RIED OUT IN ACCORDANCE WITH THE
REQUIREMENTS OF THE PROVINCIAL
AUTHORITIES HAVING JURISDICTION
AND IN ACCORDANCE WITH THE RE-
QUIREMENTS OF THE CAN/CSA-B149.1
INSTALLATION CODE.
LA CONVERSION DEVRA êTRE EFFECTUéE
CONFORMéMENT AUX RECOMMANDA-
TIONS DES AUTORITéS PROVINCIALES
AYANT JURIDICTION ET CONFORMé-
MENT AUX EXIGENCES DU CODE
D'INSTALLATION CAN/CSA-B149.1.
Gas conversion kits are available to adapt your
appliance from the use of one type of gas to
the use of another. These kits contain all the
necessary components needed to complete
the task including labeling that must be af-
fixed to ensure safe operation.
Kit part numbers are listed here and the
following steps detail the conversion pro-
cedure. Refer to the instructions provided
with the conversion kit when performing any
gas conversion.