35
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Natural Gas to Propane Gas
Conversion Kits
Fireplace
Type
Cat. No.
(model)
Millivolt
85L65
FGCK-DMOMNP
Electronic
85L79
FGCK-DMOENP
Propane Gas to Natural Gas
Conversion Kits
Fireplace
Type
Cat. No.
(model)
Millivolt
85L72
FGCK-DMOMPN
Electronic
85L86
FGCK-DMOEPN

INSTALLATION INSTRUCTIONS

Step 1. TURN OFF THE GAS SUPPLY TO THE
APPLIANCE and disconnect power supply at the
circuit breaker. Ensure appliance is cold.

CAUTION: THE GAS SUPPLY SHALL BE

SHUT OFF PRIOR TO DISCONNECTING THE

ELECTRICAL POWER, BEFORE PROCEEDING

WITH THE CONVERSION.

ATTENTION : AVANT D’EFFECTUER

LA CONVERSION, COUPEZ D’ABORD

L’ALIMENTATION EN GAZ, ENSUITE, COU-

PEZ L’ALIMENTATION éLECTRIQUE.

Step 2. Remove the front glass door assembly
from the appliance (see Removing Glass Enclo-
sure Panels on Page 30). Remove the control
compartment door (see Control Compartment
Door Removal on Page 27).
Step 3. Carefully remove the logs. Exercise
care so as not to break the logs.
Step 4. Refer to Figure 60.
Remove the front burner and then the rear
burner.
FRONT OF FIREPLACE
REAR BURNER
FRONT BURNER
VENTURI
TUBE ARM
VENTURI
TUBE ARM AIR SHUTTER
ADJUSTMENT LEVER
FIREBOX SUBFLOOR
NOTE: REMOVE FRONT BURNER FIRST,
THEN REAR BURNER.

Figure 60

Millivolt Appliances
Step 5. - SIT Systems - Refer to Figure 61
on Page 36 and the instructions provided with
the kit. Using a Torx T20 (with 1/4" shank and
center hole), tool or standard flat screwdriver
remove and discard the three pressure regulator
mounting screws. Remove the pressure regu-
lator, spring, poppet, diaphragm and bushing.
Discard all removed components.
Ensure the rubber gasket installed on the back of
the replacement pressure regulator is properly
positioned and install the new pressure regula-
tor using the new screws supplied with the kit.
Tighten screws to 25 In. lb. torque.

In Canada:

THE CONVERSION SHALL BE CAR-

RIED OUT IN ACCORDANCE WITH THE

REQUIREMENTS OF THE PROVINCIAL

AUTHORITIES HAVING JURISDICTION

AND IN ACCORDANCE WITH THE RE-

QUIREMENTS OF THE CAN/CSA-B149.1

INSTALLATION CODE.

LA CONVERSION DEVRA êTRE EFFECTUéE

CONFORMéMENT AUX RECOMMANDA-

TIONS DES AUTORITéS PROVINCIALES

AYANT JURIDICTION ET CONFORMé-

MENT AUX EXIGENCES DU CODE

D'INSTALLATION CAN/CSA-B149.1.

Gas conversion kits are available to adapt your
appliance from the use of one type of gas to
the use of another. These kits contain all the
necessary components needed to complete
the task including labeling that must be af-
fixed to ensure safe operation.
Kit part numbers are listed here and the
following steps detail the conversion pro-
cedure. Refer to the instructions provided
with the conversion kit when performing any
gas conversion.

GAS CONVERSION KITS

WARNING

This conversion kit shall be installed by a qualified service agency in accor-dance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruction is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit.The qualified service agency performing this installation assumes responsibility for this conversion.

AVERTISSEMENT

Cette trousse de conversion doit être installée par un technicien agréé, selon les instructions du fabricant et selon toutes les exigences et tous les codes pertinents de l’autorité compétente. Assurez-vous de bien suivre les instructions dans cette notice pour réduire au minimum le risque d’incendie, d’explosion ou la production de monoxyde de carbone pouvant causer des dommages matériels, des blessures ou la mort. Le tecnicien agréé est responsable de l’installation de cette trousse. L’installation n’est pas adéquate ni complète tant que le bon fonctionnement de l’appareil converti n’a pas été vérifié selon les instructions du fabricant fournies avec la trousse. Le fournisseur de service qualifié ayant réalisé l'installation assume les responsabilités liées à la conversion.