Sample Specification
Lamp(s) shall be (a) DULUX® (DT/E/C) lamp(s) that pass existing Federal TCLP limits. Lamp(s) shall have an average rated life of 12,000 hours, a correlated color temperature of (3500K, 4100K or 5000K), and a CRI of 82. Lamps shall have a
Warranty Information
QUICK 60+ warranty
for OSRAM SYLVANIA lamp and ballast combination
Limited 6 month lamp warranty and a five year ballast warranty is possible if both lamps and ballasts are provided by OSRAM SYLVANIA. See
the QUICK 60+ warranty for details and restrictions.
Ordering and Specification Information
Item | Ordering | NEMA Generic |
|
|
|
| Initial | Mean | Color |
| Av. Rated | |
Number | Abbreviation | Designation | Base | Watts | Volts1 | Amps1 | Lumens | Lumens2 | Temp. | CRI | Life(hrs.)3 | |
|
|
|
|
|
|
|
|
|
|
|
| |
20566 | CF42 DT/E/C/835 | CFM42W/GZ24q/35 | 42 | 135 | 0.320 | 3200 | 2752 | 3500K | 82 | 12,000 | ||
20851 | CF42 DT/E/C/841 | CFM42W/GZ24q/41 | 42 | 135 | 0.320 | 3200 | 2752 | 4100K | 82 | 12,000 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
20866 | CF42 DT/E/C/850 | CFM42W/GZ24q/50 | 42 | 135 | 0.320 | 3200 | 2752 | 5000K | 82 | 12,000 |
*Base compatible with new proposed high temperature socket and with
1.@ 25 KHz
2.Measured at 40% (4800 hours) of rated life.
3.Based on 3 hours per start. Number of operating hours when half have failed and half are still operating.
Contact your SYLVANIA sales representative for product availability.
Ordering Guide
CF | 42 | DT | / | E | / | C | / | 835 |
Compact | Wattage | DULUX |
| For electronic |
| Constant |
| 82 CRI |
Fluorescent |
| Triple |
| ballasts |
| luminous |
| 35 = 3500K |
|
|
|
|
|
| flux |
| 41 = 4100K |
|
|
|
|
|
|
|
| 50 = 5000K |
Dimensions
|
|
|
|
|
|
|
|
|
|
|
|
|
| (A) | (B) | (C) | (D) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| B | MOL | Max. Base Face to | Max. Base Width | Guide Post | ||||
A |
|
|
|
|
|
|
|
| [in. (mm)] | Top of Lamp [in. (mm)] | [in. (mm)] | [in. (mm)] | |||||
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| CF42DT/E/C | 6.42 (163) | 5.79 (147) | 1.90 (49) | 0.62 (16) | |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| C |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| D |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
Technical Information
OSRAM SYLVANIA
National Customer
Service and Sales Center
18725 N. Union Street
Westfield, IN 46074
Industrial Commercial
Phone:
Fax:
National Accounts
Phone:
Fax:
OEM/Special Markets
Phone:
Fax:
Display/Optic
Phone:
Fax:
In Canada
OSRAM SYLVANIA LTD.
2001 Drew Road
Mississauga, ON L5S 1S4
Industrial Commercial
Phone:
Fax:
Special Markets
Phone:
Fax:
Visit our website: www.sylvania.com
Relative Light Output vs Ambient Temperature*
| 110 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 100 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(%) | 90 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
OUTPUT | 80 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
70 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
60 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
LIGHT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
50 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
RELATIVE | 40 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
20 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 5 | 10 | 15 | 20 | 25 | 30 | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 | 75 | 80 | 85 | 90 | 95 |
| 41 | 50 | 59 | 68 | 77 | 86 | 95 | 104 | 113 | 122 | 131 | 140 | 149 | 158 | 167 | 176 | 185 | 194 | 203 |
AMBIENT TEMP. (Deg. C & Deg. F)
|
| DULUX DT/E/C | DULUX T/E/IN |
|
| ||
|
|
|
|
* Graph measured in
Typical Fluorescent Lamp Mortality
| 100 | |
| 90 | |
SURVIVING | 80 | |
70 | ||
| ||
| 60 | |
PERCENT | 50 | |
40 | ||
| 30 |
20
10
0
0 | 20 | 40 | 60 | 80 | 100 | 120 | 140 | 160 | 180 | 200 |
PERCENT RATED LIFE
SYLVANIA and QUICK 60+ are registered trademarks of OSRAM SYLVANIA Inc.
DULUX and QUICKTRONIC are registered trademarks of OSRAM GmbH, used under license.
© 2009 OSRAM SYLVANIA 3/08 Photography