OPERATING INSTRUCTIONS
06/01/2008
Replacement Procedures
I. Replacing the Heating Element
1.Turn heater/blower switches OFF, and disconnect from power source.
2.Use a flat screwdriver to remove (pry open) the wiring cover under the stainless nozzle tube.
3.Remove the stainless nozzle by removing the two mounting screws, and the
4.Disconnect the KTC+ (Yellow), KTC- (Red), HTR1, HTR2 connections from the wiring terminal as shown. Total of four wires.
5.Remove the old element, pulling the KTC and HTR wires through the plastic support tower.
6.Install new element by reversing steps
II. Replacing the Temperature Controller
1.Turn heater/blower switches OFF, and disconnect from power source.
2.Remove the four screws which secure the black plastic top cover plate.
3.Remove the four screws which attach the aluminum base plate to the main heater plastic structure.
4.With the top cover plate and the aluminum plate removed, you now have access to the top and bottom mounting tabs on the temperature controller.
5.While lifting the top and bottom white plastic mounting tabs, gently push the temperature controller halfway out of the faceplate.
6.Using masking tape or other method, mark each wire going to the back of the controller with a number
7.Using a small screwdriver, loosen and remove the wires from the terminals at the rear of the temperature controller.
8.Remove temperature controller completely from the faceplate.
9.Install new temperature controller halfway into faceplate.
10.Reconnect the wires according to the terminal number and ID marking from step #4.
11.Press controller into faceplate while engaging the white mounting tab securely.
12.Replace the black plastic top cover plate and reattach mounting screws.
OSRAM SYLVANIA
131 Portsmouth Avenue
Exeter, NH 03833 USA
+
+
,:
www.sylvaniaheaters.com | 6 |