SPECIFICATION DATA |
|
|
|
|
|
|
|
Catalog # | Date | Type | T8 POWERSENSE |
Project | Prepared by |
| |
Comments |
|
| High Efficiency |
|
|
|
|
QUICKTRONIC® POWERSENSE® Controls Information
|
| Fluorescent |
|
|
| Building | |
| Controls | Powerline | Photo | Occupancy | Management | ||
| Manufacturer | Controllers | Controllers | Cells | Sensors | Systems | |
| SYLVANIA ELOGIC™ Controls |
|
|
|
|
| |
E | x | x | x | x |
| ||
www.sylvania.com |
| ||||||
S |
|
|
|
|
|
| |
|
|
|
|
|
| ||
CONTROLS | Encelium |
|
|
|
|
| |
N E | www.encelium.com |
|
|
|
| x | |
S | Hunt Dimming |
|
|
|
|
| |
ER |
|
|
|
|
| ||
www.huntdimming.com | x | x | x | x | x | ||
W | Lehigh Electronic Products |
|
|
|
|
| |
O |
|
|
|
|
| ||
www.lehighdim.com | x | x | x | x | x | ||
P | |||||||
| Leviton Lighting Controls |
|
|
|
|
| |
| www.leviton.com | x | x | x | x |
| |
| Lightolier Controls |
|
|
|
|
| |
| www.lolcontrols.com | x | x | x | x | x | |
| Lithonia Controls |
|
|
|
|
| |
| www.lithonia.com | x | x | x | x | x | |
| Lumisys |
|
|
|
|
| |
| www.lumisys1.com | x | x |
|
| x | |
| PCI |
|
|
|
|
| |
| www.pcilightingcontrols.com |
| x | x |
|
| |
| Sensorswitch |
|
|
|
|
| |
| www.sensorswitch.com |
|
| x | x |
| |
| Siemens Energy & Automation |
|
|
|
|
| |
| www.sea.siemens.com |
|
|
|
| x | |
| Starfield Controls |
|
|
|
|
| |
| www.starfieldcontrols.com |
| x | x | x | x | |
| The Watt Stopper, Inc |
|
|
|
|
| |
| www.wattstopper.com |
|
| x | x |
| |
|
|
|
|
|
|
|
Please contact controls manufacturers to order/specify controls. For the latest controls list go to www.sylvania.com
Also for more information, check out the LCA (Lighting Controls Association) site: www.aboutlightingcontrols.org
Dimensions:
Controls Guide
Warning
Install and wire these ballast and controls in accordance with the National Electrical Code (NEC), all applicable Federal, State and local electrical codes, as well as the specific instructions provided with the compatible control that you purchased. Installation should be performed by qualified personnel only.
These instructions are guidelines only. Installation may vary for different controls/ fixtures/applications. Be sure to follow the
1 & 2 lamp enclosure
Overall: 9.5" L x 1.68" W x 1.0" H (241 x 43 x 25 mm)
Mounting: 8.90" (226 mm)
Weight: 1.1 lbs each (500 g)
3 & 4 lamp enclosure
Overall: 16.7" L x 1.68" W x 1.0" H (425 x 43 x 25 mm) Mounting:16.2" (411 mm)
Weight: 2.1 lbs each (950 g)
Wiring:
Leads Only
Height 25.4mm (1.0")
Height
8.70 mm Slot
Width
Mounting
Length
Length | Width |
| 43mm |
| (1.68") |
Mounting 411.3mm (16.2") Length
425mm
(16.7")
control instructions and all applicable codes and standards when installing dimming systems.
Please contact controls manufacturer listed in the OSRAM SYLVANIA Inc. controls cross reference for compatible controls and instruction wiring.
NOTES:1.Dimming ballasts source < 0.5mA
2.Powerline controls must be rated for the type (e.g. Fluorescent
Input & Control | POWERLINE CONTROL | |||||
Wiring Options: | ||||||
|
| BLACK | LINE | BLACK | ||
| LINE |
| ||||
| NEUTRAL |
| WHITE | NEUTRAL | WHITE | |
|
|
|
| |||
| Class 1 or | VIOLET (+) |
| VIOLET (+) | ||
| Class 2 | < 0.5mA | GREY | INSULATE | ||
| GREY | |||||
|
| |||||
|
|
|
| UNUSED LEADS |
|
Control Specifications/model numbers may change.
Please consult manufacturers listed for their latest control models and to order their controls.
OSRAM SYLVANIA
National Customer Service and Sales Center
Specifications subject to change without notice.