Scanning 2 - 3
Fast warble beep Aborting MPDF sequence.
Low/high beeps Flushing an already empty MPDF buffer.
ADF Programming: Normal Data Entry. Duration of tones are short.
High/low beeps Enter another digit. Add leading zeros to the front if necessary.
Low/low beeps Enter another alphabetic character or scan the End of Message bar code.
High/high beeps Enter another criterion or action, or scan the Save Rule bar code.
High/low/high/low beeps Rule saved. Rule entry mode exited.
High/low/low beeps All criteria or actions cleared for current rule, continue entering rule.
Low beep Delete last saved rule. The current rule is left intact.
Low/high/high beeps All rules are deleted.
ADF Programming: Error Indications. Duration of tones are very long.
Low/high/low/high beeps Out of rule memory. Erase some existing rules, then try to save rule again. (It is not
necessary to re-enter the current rule.)
Low/high/low beeps Cancel rule entry. Rule entry mode exited be cause of an error or the user asked to exit
rule entry.
Low/high beeps Entry error, wrong bar code scanned. Re-enter criterion or action. All previously
entered criteria and actions are retained. Criteria or action list is too long for a rule.
Host Specific
USB only
4 short high beeps Digital scanner has not completed initialization. Wait several seconds and scan again.
Low/medium/high beeps
upon scanning a USB device
type
Communication with the bus must be established before the digital scanner can
operate at the highest power level.
Low/medium/high beeps
occur more than once. The USB bus can put the digital scanner in a state where power to the digital scanner
is cycled on and off more than once. This is normal and usually happens when the PC
cold boots.
RS-232 only
1 short high beep A <BEL> character is received and Beep on <BEL> is enabled.
Table 2-1
Beeper Definitions (Continued)
Beeper Sequence Indication