Tanaka TCP-210 manual Assembly Procedure, Operating Procedures, TCP-25/210/381, Strainer Fig, Fuel

Models: TCP-381 TCP-25 TCP-210

1 10
Download 10 pages 63.72 Kb
Page 5
Image 5
3. Assembly Procedure

TCP-25/210/381

3. Assembly Procedure

Hose to pump connection. (Fig. 1-1)

Care must be taken to ensure that tight connection is made between the female unions, and the male pump stubs.

NOTE!

An air leak at either union will greatly reduce the pump efficiency or no water is pumped at all.

Strainer (Fig. 1-2)

CAUTION!

A strainer should always be used on the suction hose, to prevent debris from entering the pump body, and causing possible damage to the impeller.

4. Operating Procedures

Fuel

Always use branded 89 octane unleaded gasoline.

Use Tanaka two-cycle oil or a quality two-cycle oil at mixing ratio of 25-50:1 (Gasoline (A) : Oil (B)), only for the state of California at 50:1.

Never use multi-grade oil (10 W/30) or waste oil.

Always mix fuel and oil in a separate clean container.

Always start by filling half the amount of fuel, which is to be used. Then add the whole amount of oil. Mix (shake) the fuel mixture. Add the remaining amount of fuel.

Mix (shake) the fuel-mix thoroughly before filling the fuel tank.

Owner’s Manual

Fueling

Hose to pump connection. (Fig. 1-1) WARNING!

Always shut off the engine before refueling.

Slowly open the fuel tank, when filling up with fuel, so that possible over-pressure disappears.

Tighten the fuel cap carefully, after fueling.

Always move the unit at least 3 m (10 ft.) from the fueling area before starting.

Before fueling, clean the tank cap area carefully, to ensure that no dirt falls into the tank. Make sure that the fuel is well mixed by shaking the container, before fueling.