19
Models BC10/BW11 Important: Tothe Operator
Section 5 Important: To the Operator

Control Switch

When placed in the “ON” position, the agitator
activates to blend product.
Figure 1

Foot Pedal

A grounded foot pedal allows the operator to use both
hands to mix product.
Figure 2
Note: Some International units are not equipped wit h
this feature.

Reset Switch

The reset switch is located above the control switc h on
the front panel. The reset switch protects the motor
from an overload condition. If an overload occurs, the
reset mechanism will trip. To properly reset the unit,
make sure the control switch is in the “OFF” position.
Press the reset switch and resume operation.
Figure 3

Splash Guard

The splash guard functions as a built-in cup limiter
which prevents the cups from agitator penetration.
The splash guard also helps keep the inside of the
housing clean.
The splash guard for the Model BC10 (counter- top)
slides up and down on stainless steel rods. The splash
guardfor the Model BW11 (wall mount) r otates upward
for easy operation.