Taylor Assembly, General Operation, Care and Maintenance, Dashpot Feature Model THD32D only

Models: THD32

1 2
Download 2 pages 58.66 Kb
Page 2
Image 2
Assembly

Congratulations on your purchase of a Taylor® Heavy Duty Mechanical Portion Control Scale. Your Taylor® Scale is an example of superior design and craftsman- ship. Please read this instruction manual carefully before use. Keep these instructions handy for future reference.

Assembly

1.The THD32 and THD32D models are shipped with their platforms wrapped in a corrugated insert with wing nuts holding them in. Remove the wing nuts and attach the platform to the top of the post, securing with the wing nuts.

2.The platform will assemble or is assembled to the inverted “U” shape post on top of the scale. Remove the (2) wood inserts that are taped to the posts and discard. (all models)

General Operation

1.Place the scale on a hard, level surface.

2.Before using the scale, allow it to reach room temperature, then perform the following steps:

A.Place weight on scale and allow pointer to come to rest.

B.Remove weight and allow pointer to come to rest.

C.After repeating this cycle two or three times, adjust pointer to zero using adjustment knob located on top of scale body, beneath platform, and repeat the adjustments until zero is stabilized.

3.If scale is relocated, readjustment to zero may be required. To do so, repeat above steps. When weighing, evenly distribute weight on platform.

Dashpot Feature (Model THD32D only)

remove. The dashpot is attached to the rear panel of the scale case.

2.There is a red slotted head brass screw with a coil spring under it. Turn the screw clockwise to increase the dampening affect and counter clockwise to lessen. Be careful when tightening to prevent bottoming the adjustment screw and potentially stripping the threads in the plastic body of the dashpot.

3.Reinstall the cover by placing the 2 tabs at its bottom into the slots in the scale case and attach at the top with one screw as it was.

Care and Maintenance

1.The body and mechanism are not dishwasher safe. Immersing the scale in water may trap liquid between lens and body that can not be effectively dried-out. Damage will void warranty.

2.Caution…An occasional wiping with a soft cloth and mild soap will keep your Taylor® scale clean and attractive. Do not use abrasive cleaners. Your Taylor® scale does not require oiling or lubrication of any kind.

3. Do not tamper with unit’s internal components. Doing so will invalidate the warranty on this unit and may cause damage. The unit contains no user-serviceable parts.

4.The lens can be removed by first pulling the bezel away from the scale case (see Fig. 1), then remove the lens (see fig. 2). You can clean the inside of the lens this way, but be careful to not bend the red pointer. Do the reverse to reattach.

This model has an adjustable air dampener (dashpot) that reduces the platform oscillations when a weight is applied. It is adjusted by the factory for proper operation. If adjustment is necessary:

1.While facing the scale, turn it so the left side is facing you. Remove one screw at the top of the side panel, tip it outward and lift up to

Fig.1

Fig.2

Page 2
Image 2
Taylor THD50, THD100 Assembly, General Operation, Care and Maintenance, Dashpot Feature Model THD32D only