Team Products PMP1200 PROBLEM TV Does Not Work, ReasonSolution, Troubleshooting

Models: PMP1200

1 6
Download 6 pages 8.13 Kb
Page 5
Image 5
Troubleshooting

 

 

 

 

PMP1200 Models

 

 

 

 

 

 

 

 

Troubleshooting

 

 

 

PROBLEM: Low or No Output Voltage

 

 

 

 

 

Reason

Solution

 

 

 

 

 

 

 

 

 

 

Poor contact with

Clean terminals

 

 

 

 

 

 

 

 

battery terminals.

thoroughly. Reattach

 

 

 

 

 

 

 

 

 

 

 

 

 

battery clips.

 

 

 

 

 

 

 

 

 

 

Using incorrect type of

Use true RMS reading meter.

 

 

 

 

 

 

 

 

voltmeter to test

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

output voltage.

 

 

 

 

 

 

 

PROBLEM: Red LED On

 

 

 

 

 

Reason

Solution

 

 

 

 

 

 

 

 

 

 

Battery voltage below

Recharge or replace battery.

 

 

 

 

10.0 ± 0.5 volts.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Equipment being operated

Use a higher capacity inverter

 

 

 

 

 

 

 

 

draws too much power.

or do not use this equipment.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inverter is too hot (thermal

Allow inverter to cool.

 

 

 

 

 

 

 

 

shutdown mode).

Check for adequate ventilation.

 

 

 

 

 

 

 

 

 

Reduce the load on the

 

 

 

 

 

inverter to rated continuous

 

 

 

 

 

power output

 

 

 

 

 

 

 

 

 

 

Unit may be defective.

See Warranty and call

 

 

 

 

 

 

 

 

 

Customer service at

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-888-231-4022.

 

 

 

 

 

7

 

 

 

 

 

 

Owner’s Manual

 

 

 

 

 

 

 

Troubleshooting

 

 

 

PROBLEM: TV Interference

 

 

 

 

 

Reason

Solution

 

 

 

 

 

 

 

 

 

Electrical interference from

Add an AC interference filter on

 

 

 

 

 

 

the inverter.

to theTV power cord. Refer

 

 

 

 

 

 

 

 

 

 

toTV and audio section of

 

 

 

 

this manual.

 

 

 

 

 

 

PROBLEM: Low Battery Alarm On All The Time

ReasonSolution

 

 

Input voltage below 10.5 ± 0.5 volts.

Keep input voltage above 10.5±0.5

 

 

 

 

 

volts to maintain regulation.

 

 

 

 

 

 

 

 

 

 

 

 

Poor or weak

Recharge or

 

 

battery condition.

replace battery.

 

 

 

 

 

 

 

 

 

 

Inadequate power being

Make sure connection is secure.

 

 

 

 

delivered to the inverter

Use lower gauge wire. Keep

 

 

 

 

or excessive voltage drop.

wire length as short as possible.

 

 

 

 

PROBLEM: TV Does Not Work

 

 

Reason

 

Solution

 

 

 

 

 

 

 

TV does not turn on.

 

Try turning the inverter

 

 

 

 

 

 

 

ON/OFF/ON.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ContactTV manufacturer for

 

 

 

 

start up surge and power

 

 

 

 

consumption.

 

 

 

 

 

 

 

 

 

A larger inverter may

 

 

 

 

be required.

 

 

 

8

 