Team Products PMP3000 Troubleshooting, PROBLEM Low or No Output Voltage, PROBLEM Red LED On

Models: PMP3000

1 6
Download 6 pages 43.76 Kb
Page 5
Image 5
In Review

PMP3000 Models

In Review

Never attempt to operate the inverter from any other power source other than a 12-volt battery.

When connecting and using the inverter, make sure that the inverter is positioned far away from any potential source of flammable fumes or gases.

Make certain that the power consumption of the equipment you wish to operate is compatible with the capacity of the inverter. Do not exceed 3000 watts in total power, or 1600 watts for each individual AC outlet.

When attempting to operate battery chargers, monitor the temperature of the battery charger for approximately 10 minutes. If the battery charger becomes abnormally warm, disconnect it from the inverter immediately.

Use only 30 amp spade type fuses for the inverter.

When operating the inverter with an automobile or marine battery, start the engine every 30 to 60 minutes and let it run for approximately 10 minutes to recharge the battery.

In the event of a continuous audible alarm or an automatic shut down of the unit, turn the inverter OFF immediately. Do not turn the inverter ON again until the source of the problem has been identified and corrected.

To avoid battery drain, always disconnect the inverter when not in use.

Do not expose the inverter to rain or moisture.

Avoid placing the inverter near sources of heat or in direct sunlight.

While in use, make sure that the inverter is properly ventilated.

For best operating results, make sure the unit is placed on a flat surface.

 

 

 

Owner’s Manual

 

 

 

 

Troubleshooting

 

PROBLEM: Low or No Output Voltage

 

 

 

Reason

Solution

 

 

 

 

 

 

Poor contact with

Clean terminals

 

 

 

 

battery terminals.

thoroughly. Reattach

 

 

 

 

 

 

 

battery clips.

 

 

 

 

 

 

Using incorrect type of

Use true RMS reading meter.

 

 

 

 

voltmeter to test

 

 

 

 

 

 

 

 

 

output voltage.

 

 

 

PROBLEM: Red LED On

 

 

 

Reason

Solution

 

 

 

 

 

 

Battery voltage below

Recharge or replace battery.

 

 

10.0 ± 0.5 volts.

 

 

 

 

 

 

 

 

 

 

 

 

 

Equipment being operated

Use a higher capacity inverter

 

 

 

 

draws too much power.

or do not use this equipment.

 

 

 

 

 

 

 

 

Inverter is too hot (thermal

Allow inverter to cool.

 

 

 

 

shutdown mode).

Check for adequate ventilation.

 

 

 

 

 

Reduce the load on the

 

 

 

inverter to rated continuous

 

 

 

power output

 

 

 

 

 

 

Unit may be defective.

See Warranty and call

 

 

 

 

 

Customer service at

 

 

 

 

 

 

 

 

 

1-888-231-4022.

 

 

 

 