TechniSat SkyFunk 3 2 manual Trouble-shooting guide, Technical data

Models: SkyFunk 3 2 3

1 8
Download 8 pages 59.02 Kb
Page 8
Image 8

6 Trouble-shooting guide

Problem

 

Possible cause

 

 

 

No picture, no sound

>

Mains switch or receiver and/or transmitter

 

 

not switched on

 

>

Cable connections faulty

 

>

Receiver and transmitter set to different

 

 

channels

 

 

 

Interference in transmission of

>

Antennae of the system not aligned optimal-

picture and sound

 

ly

 

>

Interference on the channel selected. Reme-

 

 

dy: select different transmission channel.

 

>

Proximity to a microwave oven that is in

 

 

operation, causing interference.

 

>

Distance between transmitter and receiver

 

 

too great.

 

 

 

Transmission of remote control

>

Faulty cable connection

signals not working

>

No line of sight between IR remote control

 

 

and receiver, resp. between IR transmitter

 

 

and signal source.

 

 

 

Transmission interrupted periodi-

>

Several receiver channels set, this leads to

cally

 

an automatic alternation between receiving

 

 

channels.

 

 

 

7 Technical data

Transmitter

Output level

 

10 dBm

 

 

Transm. frequency

2,4 bis 2,4835 GHz

Modulation

 

FM (Video u. Audio)

 

 

 

Level

Video in

1Vss

 

Audio in

1Vss

 

 

 

Impedance

Video in

75 Ohm

 

Audio in

600 Ohm

 

 

Power supply

9V DC 90mA

Dimensions

 

102 x 41 x 115mm

Weight

 

130g

 

 

 

Receiver

Video level

1Vss

Audio level

1Vss

 

 

Sensitivity

-85 dBm

 

 

Transmission fre-

434 MHz

quency of remote

 

control signals

 

 

 

IPower supply

9V DC 90mA

Dimensions

102 x 41 x 115mm

Weight

130g

 

 

110903