Operating Basics
6TSG 601 User Manual
GSpecify the peak–to–peak amplitude of the serial output, from
600 to 1000 mV (page 8).
GChoose the video components (Y, Cr, Cb) to be included in the
serial output (page 8).
GSpecify 8- or 10-bit video sample words (page 9).
HEmbed CRC information (used for “Error Detection and
Handling,” or EDH) in the output to detect or simulate errors
originating in the serial data path (page 9).
HAdd an ID message to the video signal, and place it where you
want in the picture (pages 10, 11).
HStore up to eight ID messages for later use (pages 10, 16).
HCreate a sequence of (up to four) stored ID messages that will
cycle continuously in the output (page 11).
HEmbed Audio information in the serial video data path (page 12)
HSimulate the effect on your system of 50 m (164 ft.) of coaxial
cable (page 15).
HDetect improper termination of the serial video signal path
(page 15).
HSave all the current instrument settings as a “Preset” for later
recall (page 16).
Outputting Serial Video Test Signals
1. Connect the Serial Video Output of the instrument to your
system. Use 75 Ω cable and be sure that the signal path is
terminated properly.