EDIT Menu
Specification of subsequent time ranges use the component menu range( item. The clock frequency is obtained from the total time (period) set with range() and the waveform point count set with Setting, thus:
Clock frequency + | Waveform point count |
Equation period |
In this example, you will create a sine wave with a period of 1ms, using the following equation:
range(0,1ms) | Time range |
sin(2*pi*x) | Equation |
1.Select Operation from the bottom menu.
2.After range(0, in the equation list use the numeric keys and the unit keys to enter 1, ms. The expression now reads range(0,1ms.
3.Using the general purpose knob, select ) from the component menu.
4.Press VALUE or ENTER on the front panel. The ) that you selected in the component menu will be inserted in front of the position of the cursor (I) , in the inverted line cursor in the equation list. The expression now reads range(0,1ms).
5.Press the key. The inverted line cursor will move to the next line.
6.Using the general purpose knob, select sin( from the component menu.
7.Press VALUE or ENTER on the front panel. The expression sin( will appear on the screen.
8.Using the numeric keys, enter 2. The expression now reads sin(2.
9.Repeat steps 6 and 7 to enter *, pi, *, x, and ). The expression now reads sin(2*pi*x).
Using the Front Panel Buttons in Editing. The functions of the CURSOR, VALUE, and ENTER button affect the operation of the general purpose knob and the cursor. Here are details on these functions.
CURSOR. When you press the CURSOR button, you can move the inverted line cursor and the cursor (I) with the general purpose knob. Each time you press the CURSOR button, the cursor that can be moved with the general purpose knob toggles between the inverted line cursor and the cursor. While the inverted line cursor can be moved with the general purpose knob, you can also move the inverted line cursor directly to the desired line by using the numeric keys to enter the desired line number.
AWG2021 User Manual | 3 143 |