3.GENERAL PRODUCT SPECIFICATIONS

Dimensions:

5.3 x 4.0 x 1.375 inches

Weight:

1 lb

Voltage Supply: Standard Model:

40 to 270VDC

 

40 to 270VAC, 50/60Hz

LV Model (Suffix “-LV”):

9 to 36VDC

Current Requirements: (See Section 4 for Power Down Modes)

MIU2.4:

 

 

 

 

12VDC

24VDC

125VDC

120VAC

220VAC

65mA

27mA

7.5mA

6.5mA

5.5mA

MIU9.6:

 

 

 

 

12VDC

24VDC

125VDC

120VAC

220VAC

115mA

57mA

11mA

10mA

9mA

MIU14.4:

 

 

 

 

12VDC

24VDC

125VDC

120VAC

220VAC

160mA

69mA

14mA

12mA

9mA

MIU28.8:

 

 

 

 

12VDC

24VDC

125VDC

120VAC

220VAC

205mA

125mA

16mA

15mA

11mA

Surge Protection:

Power Supply:

8kVrms

 

 

 

Analog Line:

5kVac (MIU2.4 & 9.6)

 

 

 

3.75kVac (MIU14.4 & 28.8)

 

 

Digital Line:

ESD ± 10kV

 

Operating Temperature:

-40 to +85 deg C

Operating Humidity:

 

0 to 90% (non-condensing.)

Storage Temperature:

 

-55 to 100 deg C

MIU Installation, Operation & Diagnostics Edition: March 30, 1998

Page 5

Page 7
Image 7