AUDIOCOM " INTERCOM SYSTEMS
MODEL PS-1 FLUSH-MOUNT POWER SUPPLY
INSTALLATION AND OPERATION INSTRUCTIONS
GENERAL DESCRIPTION | WARNING |
The Telex AudiocomT"Model
SPECIFICATIONS
Power Requirements:
Output Voltage: 24 Vdc regulated (less than 50 millivolts ripple)
Output Current:
-500 milliamps maximum continuous
-700 milliamps maximum intermittent
-240 milliamps short circuit current limiting
Channel Terminating Impedance (provided by
Connectors:
-Intercom Channel: Three screw terminals with wire clamps for No.
-Power: Three wire pigtails
THE
INSTALLATION
1.Ac power should be supplied from a circuit protected by a service fuse or circuit breaker with a maximum rating of 15 amps. Connect ac power to the black and white leadwires; connect ground to the green wire.
2.To power an intercom channel: Connect the intercom channel to the CHANNEL terminals, and connect intercom dc return to the SHLD terminal.
To locally power a speaker station: Connect the speaker station positive terminal to either one of the
-.
the +24 and PH terminals. (This jumper is used only when the speaker station is phantom powered from the intercom channel.)
3.Mount the
1
J
Model
TELEX.
I
TELEX COMMUNICATIONS, INC. 9600 Aldrich Ave. So., Minneapolis, MN 55420 U.S.A.