Texas Electronics, Inc.
5529 Redfield St.
Dallas, Tx 75235
Model
Remove cover of
Refer to Pressure vs Voltage/Current Table under the Barometer section of the service manual.
|
|
|
| MICRO |
|
|
|
|
|
|
|
| SWITCH |
|
|
|
|
|
|
|
| USA |
|
|
|
|
|
|
| U1 | P1 | P2 |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| C1 |
| C99 | C4 |
|
|
|
|
|
|
|
| ||
|
|
|
| C3 | U2 |
|
|
|
|
|
|
|
|
|
|
| |
|
|
| D3 | R11 |
|
| R3 |
|
|
|
|
|
|
|
| ||
| TB1 |
| R12 |
|
| R4 |
| |
| D2 | R8 |
|
| R2 |
| ||
|
|
|
|
|
| |||
|
|
|
| R9 |
|
| R1 |
|
|
|
| R21 | C98 |
|
| R18 | R22 |
|
|
| D4 | R13 |
|
| R19 |
|
|
|
|
| R14 |
|
| R20 |
|
|
|
| D1 | R16 |
|
|
|
|
SIG. | COM. | +12V | COM. | C7 |
|
| C5 | REF |
|
|
| ||||||
|
|
|
| |||||
|
|
| R17 |
| ||||
|
|
|
| C6 |
|
| C2 | SPAN |
ELECTRIC BAROMETER |
|
|
|
| ||||
|
|
|
|
| ||||
MODEL NO. |
| U3 |
| R15 |
| |||
|
|
|
|
|
|
|
| |
S/N 102795 |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| NULL |
MODEL TB-2012M BAROMETRIC PRESSURE SENSOR
(Shown with cover removed)
DESCRIPTION
The Texas Electronics, Inc.
SPECIFICATIONS
Calibration Range:
Supply Voltage:
Current Draw:
Accuracy:
Operating Temperature Range:
Calibrated Temperature Range:
Output:
Optional Output:
Weight:
Dimensions:
Warranty:
26" to 32" or 878 mb to 1080 mb 12 to 15 VDC
<15 mA +/- 1.3mb
2 lb. or 8.9 N or .907 kg. w/ 60 ft. or 18.3 meters cable
6" or 15.24 cm H x 5" or 12.7 cm W x 3" or 7.62 cm D (Single enclosure: double enclosure also available)
3 year