Therma-Stor Products Group PN 4027300 owner manual The Phoenix FireBird, •Two 8’ Power Cords

Models: PN 4027300

1 7
Download 7 pages 14.58 Kb
Page 1
Image 1
Owner’s Manual — Phoenix FireBird

PO Box 8680 • Madison, WI 53708

Owner’s Manual — Phoenix FireBird

Installation, Operation and Service Instructions

Important Instructions – Read and Save These Instructions

The FireBird portable, heavy duty electric heater features a built-in 50-amp twist lock receptacle designed to work with standard 30 or 50 amp power sources—select the setting using the HIGH/LOW switch.

At the 50-amp setting, the FirebBird produces 31,000 BTU’s—thats 360 CFM with a 80°F temperature rise. In an area with below freezing temperatures the FireBird can produce 360 CFM of air over 100 degrees. Using the 30-amp setting the FireBird produces 18,000 BTU’s—giving a 46°F temperature rise. Internal temperature cutouts prevent the FireBird from overheating an area while the FireBird’s externally located thermostat terminals provide a means to control the heat from anywhere in the drying space.

The Phoenix FireBird

ETL Certified, UL Listed

30 or 50 Amp operation (18,000 BTU/31,000 BTU)

30 Amp = 24 Actual Amp Draw and 46ºF Temperature Rise 50 Amp = 40 Actual Amp Draw and 80ºF Temperature Rise

Two 8’ Power Cords
(1 dryer, 1 range) included with unit

360 CFM

Multiple air filter options
Standard MERV-11, MERV-14
Multiple ducting options

12” intake, 12” supply

Detachable 12” Duct Collar stores in lid with room for power cords

Stainless steel cabinet

Phoenix FireBird

PN 4027300

Specifications subject to change without notice.

TS-407

Revised 12/07

Toll-Free 1-800-533-7533



www.usephoenix.com • sales@thermastor.com