MODEL OPTIONS
There are two sizes of Thermador Masterpiece®
Gas Cooktops to choose from —
INSTALLATION CONSIDERATIONS
The information in this design guide provides key features, product dimensions, cutouts and installation specifi cations. Before installing a Thermador Masterpiece Gas Cooktop, be sure to verify the cutout dimensions and electrical/gas connections. Also, always consult with the installation manual packed with the product for complete details before installing.
Thermador Masterpiece Gas Cooktops may be installed above a Thermador Single
Thermador Masterpiece Gas Cooktops may also be installed above a Thermador Warming Drawer to create a convenient cooking center. Refer to the warming drawer section for additional specifi cations.
Solid surface countertops require a special cutout size and special installation. For example, heat refl ective tape or rounded corners may be necessary. Contact the countertop manufacturer for instructions specifi c to your countertop.
VENTILATION REQUIREMENTS
GAS COOKTOPS PLANNING INFORMATION
ELECTRICAL AND GAS SPECIFICATIONS
Be sure your appliance is properly installed and grounded by a qualifi ed technician. Installation, electrical and gas connections, and grounding must comply with all applicable local codes. Thermador Masterpiece Gas Cooktops are equipped with a
MODEL | REQUIRED CIRCUIT BREAKER |
| 120V, 60 Hz |
|
|
SGS304FS | 15 Amp |
|
|
SGS305FS | 15 Amp |
|
|
SGSX305FS | 15 Amp |
|
|
SGS365FS | 15 Amp |
|
|
SGSX365FS | 15 Amp |
|
|
SGSL365KS | 15 Amp |
|
|
IMPORTANT: It is required that the cooktop be installed on a grounded,
Thermador Masterpiece Gas Cooktops are shipped by the factory to operate on natural gas. They must be converted for use with propane. Verify the type of gas being used at the installation site matches the type of gas used by the appliance. If the location/job site requires conversion from natural gas to propane (LP), order SNLPKITF. Field conversion must be done by qualifi ed service personnel only. Please refer to the LP Conversion Instructions for further information.
SUPPLY PRESSURE REQUIREMENTS:
Natural Gas – 7 inches water column (14.9 Millibars) minimum.
LP (Propane Gas)
NOTE: The propane gas tank must be equipped with its own high pressure regulator in addition to the pressure regulator supplied with this unit.
COOKTOPS — GAS
We strongly recommend that a Thermador Ventilation Hood be installed with all Thermador Masterpiece Gas Cooktops. The hood must be installed according to instructions furnished with the hood. Refer to the ventilation section or www.Thermador.com for a complete selection of ventilation options, blowers, and accessories.
When installing the gas cooktop with a downdraft ventilation system, provide approximately a 10 square inch opening (65 cm2) in the toekick area or other cabinet area for adequate air inlet. Refer to the downdraft ventilation section for more details.
WARRANTY
Limited warranty parts and labor (2 year)
See page 308 for additional warranty details.
DE SIGN
CER TIFIED
ELECTRICAL AND GAS LOCATIONS
The opening for the gas connection and electrical cord is located at the right rear of
Plan the installation so that the power connection is accessible from the front of the cabinet. Install a manual gas
Opening for Gas
Connection and
Electrical Cord
1”
C of Cutout
L
for 30” models: 12 15/16” (313 mm)
for 36” models: 15 15/16” (389 mm)
1.800.735.4328 THERMADOR.COM | 109 |