Specifications
Application: | Forced |
Unit Size: | 15" wide x 11 ½" high x 9" deep |
Plenum Opening: | 10¼ " wide x 9½" high |
Bypass Duct: | 6" diameter (collar supplied) |
Water Supply: | Use ¼ " copper (saddle valve supplied) |
Electrical: | Model HA1042 Drain Type with Humidistat - 24 V. 60 Hz. |
Drain Connections: | 5/8 dia. (15' vinyl hose supplied) |
Controls: | Manual air shutter Humidistat with HA1042 |
HUMIDITY REQUIREMENTS IN GALLONS PER DAY BASED ON HOUSE SIZE AND TYPE OF CONSTRUCTION (FROM ARI GUIDELINE F)
Type of |
| Size of House (sq. ft.)* |
| |||
Construction | 500 | 1000 | 1500 | 2000 | 2500 | 3000 |
| ||||||
Tight | 2.1 | 4.2 | 6.4 | 8.5 | 10.6 | 12.7 |
Average | 3.3 | 6.5 | 9.8 | 13.1 | 16.3 | 19.6 |
Loose | 4.6 | 9.2 | 13.8 | 18.4 | 23.0 | 27.6 |
*Based on 8 ft. ceiling height.
Evaporative Capacity Output
Temp°F 80° 100° 120° 140°* 160°
GPD 8.0 12.2 16.4 19.2 23.2
*Industry Standard rating conditions. 140° hot water supplied to the humidifier in heat pump applications will increase capacity by 4.3 gallons per day.
Tight House
With insulated walls and ceilings, vapor barriers, weather stripping on doors and windows, and snug doors, windows and fireplace damper (½ air change per hour)
Average House
Insulated walls and ceilings with vapor barriers, but loose storm doors, windows and fireplace damper (1 air change per hour)
Loose House
Without insulation, storm doors, storm windows, weather stripping or vapor barriers (2 air changes per hour)
Illustrations and photographs in this brochure are only representative.
Due to ongoing engineering upgrades, some variations may occur.
Form No.
© 2006 Thermo Products, LLC - North Judson, IN Phone: