Thermo Products OH11-105...E ECM Specifications, Additional Features, General, Cycle Control

Models: OL11-105...E OH11-105...E OH5-85...E OL5-85...E

1 2
Download 2 pages 41.8 Kb
Page 2
Image 2
ECM Specifications

ECM Specifications

Model Number *

OL5-85...E

OL11-105...E

OH5-85...E

OH11-105...E

CFM from .1 - .6” W/C

 

 

 

 

 

 

 

 

A/C Tonnage Selection

 

 

 

 

 

 

Cooling

 

A/C

Continuous

A/C

Continuous

A/C

Continuous

A/C

Continuous

 

CFMs

Fan

CFMs

Fan

CFMs

Fan

CFMs

Fan

(100 cfm

2 ton

800

500

800

500

800

500

800

500

steps

available

2.5 ton

1000

500

1000

500

1000

500

1000

500

for A/C)

3 ton

1200

600

1200

600

1200

600

1200

600

 

 

3.5 ton

1400

700

1400

700

1400

700

1400

700

 

Air Temperature Rise Selection

 

 

 

 

 

 

 

 

Heating CFM

Heating CFM

Heating CFM

Heating CFM

Heating

57° Rise

 

1400

 

 

1400

 

(at approx.

63° Rise

 

1260

 

1500

 

1260

 

1500

rated input

 

 

 

 

69° Rise

 

1162

 

1350

 

1162

 

1350

BTU)

 

 

 

 

 

75° Rise

 

1050

 

1245

 

1050

 

1245

 

83° Rise

 

938

 

1125

 

938

 

1125

The standard motor size may not support this cfm at high static pressures. * Model numbers end with ‘E’ to signify ECM motor.

Additional Features

General

Eliminates the need for air temp thermostat to control fan cycling by using time instead.

Selectable blower turn-on and turn-off delays to adjust comfort & efficiency (turn-on: 30, 60, 120 & 240 sec; turn off: 2, 4, 6 & 8 min)

Three blower operating choices: HEAT, COOL & FAN for best efficiency for each mode.

Reduces A/C blower speed 50% on demand to increase dehumidification.

Cooling blower delays of 10 seconds on, and 45 seconds off to enhance cooling comfort and efficiency.

Cycle Control

4 minute minimum A/C off time to reduce Short-Cycle related failures.

A high limit will cause the blower run at the selected HEAT speed. It will then run for the HEAT turn off time afterwards in the absence of a HEAT call.

Blower operation will “time out” before mode is switched between HEAT & COOL to prevent stress related evaporator failures.

Burner Cut-Off on high limit

Speed Control

Selectable air temperature (heat) rise from Return to Supply Plenum (choose from: 63, 69, 75 and 85ºF)

Selectable CFM rates for matching A/C tonnages. These CFM selections support from 2.0 to 3.5 tons.

Maximum CFM’s are limited by the maximum RPM of the ECM motor and the duct static pressure. Please refer to the manual addendum for guidelines.

Diagnostics

• Control Input LED’s indicate active thermostat input lines.

• Diagnostic LED indicate:

1.Active Operation (turn full on during burner or compressor operation)

2.A HIGH LIMIT condition. (flash on/off at 2 ½ times per second)

Form No. PL81410021002 - 6/05 - 20Ms Printed in the U.S.A.