TABULAR DATA SHEET
Outdoor Split System Heat Pump 1.5 Thru 5 Tons
MODELS: THJD18* THRU 60 13 SEER – R-410A, 1 PHASE
Physical and Electrical Data
MODEL |
| THJD18 | THJD24 | THJD30 |
| THJD36 |
| THJD42 | THJD48 | THJD60 |
| S41S3 | S41S4 | S41S4 |
| S41S4 |
| S41S4 | S41S4 | S41S4 | |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
Unit Supply Voltage |
|
|
|
|
|
|
| |||
Normal Voltage Range 1 |
|
|
|
| 187 to 252 |
|
|
| ||
Minimum Circuit Ampacity | 11.9 | 11.2 | 14.1 | 19.7 |
| 20.9 | 25.6 | 34.9 | ||
Max. Overcurrent Device Amps 2 | 20 | 15 | 20 | 30 |
| 35 | 45 | 60 | ||
Min. Overcurrent Device Amps 3 | 15 | 15 | 15 | 20 |
| 25 | 30 | 35 | ||
Compressor Type |
| Scroll | Recip | Recip |
| Recip | Recip | Recip | Scroll | |
Compressor | Rated Load | 9.0 | 8.3 | 10.6 | 14.7 |
| 15.7 | 19.4 | 26.9 | |
Amps | Locked Rotor | 48.0 | 43.0 | 54.0 | 74.0 |
| 88.0 | 88.0 | 135.0 | |
Crankcase Heater |
| No | Yes | Yes |
| Yes | Yes | Yes | No | |
Factory External Discharge Muffler | Yes | No | No |
| No | No | No | Yes | ||
Factory External Check Valve | No | No | No |
| No | No | No | No | ||
HS Kit Required with TXV 4 | No | Yes | Yes |
| Yes | Yes | Yes* | No | ||
Fan Motor Amps | Rated Load | 0.70 | 0.80 | 0.80 | 1.3 |
| 1.3 | 1.3 | 1.3 | |
Fan Diameter Inches |
| 24 | 24 | 24 | 24 |
| 24 | 24 | 24 | |
| Rated HP | 1/10 | 1/8 | 1/8 | 1/4 |
| 1/4 | 1/4 | 1/4 | |
Fan Motor | Nominal RPM | 825 | 1075 | 1075 | 850 |
| 850 | 850 | 850 | |
| Nominal CFM | 2000 | 2900 | 3000 | 3800 |
| 3800 | 3600 | 3600 | |
| Face Area Sq. Ft. | 15.7 | 18.3 | 21.0 | 23.6 |
| 23.6 | 23.6 | 23.6 | |
Coil | Rows Deep | 1 | 1 | 1 | 1 |
| 1 | 2 | 2 | |
| Fin / Inches | 22 | 22 | 22 | 22 |
| 22 | 18 | 18 | |
Liquid Line Set OD | (Field Installed) | 3/8 | 3/8 | 3/8 | 3/8 |
| 3/8 | 3/8 | 3/8 | |
Vapor Line Set OD (Field Installed) | 3/4 | 3/4 | 3/4 | 3/4 |
| 7/8 | 7/8 | 7/8 | ||
Unit Charge (Lbs. - Oz.) 5 | 6 - 6 | 9 - 6 | 9 - 0 | 10 - 0 |
| 9 - 10 | 14 - 12 | 13 - 13 | ||
Charge Per Foot, Oz. | 0.62 | 0.62 | 0.62 | 0.62 |
| 0.67 | 0.67 | 0.67 | ||
Operating Weight Lbs. | 172 | 194 | 206 | 218 |
| 218 | 285 | 284 |
*These models are shipped with a Hard Start Kit installed at the factory.
1.Rated in accordance with ANSI/AHRI Standard
2.Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3.Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4.See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5.The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
All dimensions are in inches. They are subject to change without notice.
Certified dimensions will be provided upon request.
| C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Unit |
| Dimensions |
| Refrigerant Connection | ||||
|
|
|
| (Inches) |
| Service Valve Size | ||||
|
| Model | A1 |
| B |
| C | Liquid | Vapor | |
|
|
|
|
|
| |||||
|
| 18 |
| 28 |
| 34 |
| 34 |
|
|
|
|
|
|
|
|
|
|
|
|
|
A | 24 |
| 32 |
| 34 |
| 34 |
| 3/4” | |
|
|
|
|
|
|
|
| |||
|
| 30 |
| 36 |
| 34 |
| 34 | 3/8” |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| |
|
| 36 |
| 40 |
| 34 |
| 34 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| 42 |
| 40 |
| 34 |
| 34 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 48 |
| 40 |
| 34 |
| 34 |
| 7/8” |
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
| B | 60 |
| 40 |
| 34 |
| 34 |
|
|
|
|
|
|
|
|
|
|
|
| |
|
| 1. | Including Fan Guard. |
|
|
|
ECN