WARNING

Do not use grill until leak checked.

If leak is detected at any time, STOP and call the Fire Department.

If you cannot stop a gas leak, immediately close LP tank valve and call LP gas supplier or your fire department!

Leak Testing Valves, Hoses and Regulator

1.Turn grill control knob to off.

2.Be sure connector is tightly connected to LP tank.

3.Completely open LP tank valve by turning hand wheel counter clockwise. If you hear a rushing sound, turn gas off immediately. There is a major leak at the connection. Correct before proceeding.

4.Brush soapy solution onto following connections:

LP tank valve

Regulator connection

connection

 

5."If growing" bubbles appear, there is a leak. Close LP tank valve immediately and retighten connections. If leaks cannot be stopped "do not try to repair". Call for replacement parts. Order new parts by giving the serial, model number and name of items needed to the Grill Service Center at 1-800-435-5194 U.S. or 1-800-387-6057 CAN.

6.Always close LP tank valve after performing leak test by turning hand wheel clockwise.

Fire & Ice • 23

Page 23
Image 23
Thermos 465630003 manual LP tank valve Regulator connection Connection