CTD
Less Than 10'
3'
Min
2' Min.
Termination
Figure 34
Chimney
10' | 3' |
| Min |
4.Pull up slightly on CTD to ensure locking joint has firmly engaged.
Using a
Refer to specific installation instructions included with the
Using a
Refer to specific installation instructions included with
Using a
Refer to specific installation instructions included with
Note: It is recommended that all exterior exposed metal fireplace components; such as ter- minations, flashings, storm collars and/or flue be painted with a premium quality, high tem- perature, rust preventative paint designed for metal. This is especially important when installations are made in abnormally adverse or corrosive environments; such as near lakes, oceans or in areas with consistently high humidity condi- tions. Consult the paint manufacturers instructions for proper preparation and application.
*Note: 2" clearance to combustibles required in Canada.
TEN FOOT RULE SUMMARYThe minimum chimney height above the roof and/or to adjacent walls and buildings is specified by all major building codes.
If the horizontal distance from the peak of the roof is less then 10', the top of the chimney must be at least 2' above the peak of the roof. If the horizontal distance from the chimney edge to the peak of the roof is more than 10' a chimney height reference point is established on the roof surface 10' horizontally from the chimney edge.
Figure 35
The top of the chimney must be at least 2' above this reference point. In all cases, the chimney cannot be less then 3' above the roof at the edge of the chimney.
The 2' in 10' rule is necessary in the interest of safety but does not ensure
If more than one termination is located in the same chase or within the same general proxim- ity, we suggest they should be separated in distance at least 24" horizontally from flue center to flue center and stacked or staggered vertically at least 18" apart, from the termination of one smoke exit to the termination of another smoke exit (Figure 36 ).
CTD
18"
18"
CTDT CTDT
24"
24"
Figure 36
This suggestion is provided in the interest of better operation. If the terminations are located too close to each other, smoke may migrate from one flue into the other.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
The minimum installed height of the completed fireplace system is 15' 0". The maximum height is 60' 0".
To determine the number of chimney sections and chimney components required, follow these steps:
1.Determine total vertical height of the fire- place installation. This dimension is the dis- tance from the surface the fireplace sets on to the point where smoke exits from the termination.
2.Determine the number of chimney compo- nents required, except chimney sections. This would include firestop spacers, stabilizers, roof flashing, etc.
3.The effective heights of the components are:
The Fireplace | = | 42 ¹⁄₄" |
= | 10 ¹⁄₄" | |
= | 16 ¹⁄₄" | |
= | 34 ¹⁄₄" | |
= | 46 ¹⁄₄" | |
= | 4" | |
= | 12" to 18" | |
= | 15" to 23" | |
= | 12" to 18" | |
= | 3"* |
*Required for every 30' of vertical chimney and/or 10' of offset chimney.
11