IMPORTANT: UNDER NO CIRCUMSTANCES CAN THE FIREPLACE TOP SPACERS (FIGURE 6 ) BE REMOVED OR MODIFIED, NOR MAY YOU NOTCH THE HEADER TO FIT AROUND OR BE INSTALLED LOWER THAN THE SPAC- ERS. THE HEADER MAY BE IN DIRECT CONTACT WITH THE TOP SPACERS BUT MAY NOT BE SUPPORTED BY THEM.
Note: The framed depth, 21 ³⁄₄" (552 mm) from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the 21 ³⁄₄" (552 mm) must be measured from the drywall surface. It is important that this dimension be exact.
If the appliance is to be elevated above floor level, a solid continuous platform must be constructed.
The header may rest on the top metal spacers, but must not be notched to fit around them.
Consult all local codes.
For Canadian Installations
Proceed with Steps 4 through 7.
Step 4. Attach the chimney collar enclosure kit, Model CCK1, around chimney collar with the screws provided (Figure 10 ).
Enclosure
Box
Figure 10
Step 5. Connect the 4" (102 mm) Class 0 air duct provided to the collar on the chimney collar enclosure with the screws provided in the hardware kit.
6
FIREPLACE SPECIFICATIONS
17 1/2" |
|
|
(445mm) |
|
|
40 1/2" |
|
|
(1029mm) |
| 32 7/8" |
37 3/8" | 21" | (835mm) |
(949mm) | (533m) | |
38 5/8" |
|
|
(981mm) |
| 6" |
42 3/4" | (152mm) | |
(1086mm) |
|
|
Right Corner Opening
17 1/2"
(445mm)
|
| 40 1/2" |
32 7/8" |
| (1029mm) |
(835mm) | 21" | 37 3/8" |
| (533m) | (949mm) |
38 5/8"
6"(981mm)
(152mm)42 3/4" (1086mm)
| Left Corner Opening |
10" | 10" |
(254mm) | (254mm) |
40 1/4"
(1022mm)40 1/4" (1022mm)
7 1/2
(191mm)
19 7/8"
(505mm)
10 1/2" (267mm)
Closed End | Open End |
35"
(889mm)
10"
(254mm)
15" 24"
(381mm)(610mm)
42 3/4"
(1086mm)
Top View
Figure 11
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.