9
8. ADJUSTMENT
1. The RDY indicator lights when the power is supplied to the network camera.
2. Connect the monitor output terminal to the monitor so that the picture may be displayed on the monitor.
3. Set the Flicker-reduction switch of the mode switch to "ON" position if flicker is annoying.
Flickering of the picture may interfere with the view under fluorescent lamps in the area where power
frequency is 50 Hz (CU) or 60 Hz (PL). In such cases, set the Flicker-reduction switch to "ON" position, and
the image free from flickering can be obtained.
Note
Setting the Flicker-reduction switch to "ON" makes the sensitivity lower than when set to "OFF." Set to the
"OFF" position when flicker is not annoying or when the camera is used in locations with poor lighting
conditions.
4. Determine the camera orientation.
Loosen the lock lever on the Camera Mounting Bracket, set the camera to the desired direction, then
securely fix the camera by rotating the lock lever on the bracket.
5. Adjust the angle of view with the zoom ring and focus on with the focal ring to get the best possible picture
reproduction.
When focusing
The object that was brought into focus in bright locations could be out of focus in dark conditions. In such
cases, focus the lens after turning the Focus adjustment switch of mode switch to "ON" position.
Note: After focus adjustment completion, turn the switch to "OFF" position.
Adjusting back focal length
When the distance to an object is shorter than the lens' shortest focusing distance, if the object is out of
focus, adjust the camera with the below procedures.
(1) Attach a lens to the camera.
(2) Loosen the back focal length adjustment ring fixing screw.
(3) Rotating the back focal length adjustment ring, adjust it to the optimum position.
(4) Retighten the back focal length adjustment ring fixing screw.
Back focal length
adjustment ring fixing screw
Back focal length
adjustment ring
Ceiling surface
Camera Mounting
Bracket (optional)
Lock lever
Zoom ring
Focal ring