13
IN
12V OUT
AUDIO ADJ.
PHANTOM
MIC
LINE ON
NC
VIDEO
VOL
RS485
CONTACT
LINE
IN
OUT
MIC IN
CONTACTCONTACT
IN OUT RS485
12C12C
+
RS-232C
24V
OUT
12
AUDIO
DE
UT
VIDEO OUT
Monitor
Network
Video Receiver
N-VR2010
VIDEO IN
Connect the 24 V AC or 24 V DC
when not using a PoE-compatible hub.
Note: Connect the 12 V DC terminal when using a remote controller.
Remote Controller
C-RM500
RS-485(+) RS-485(
-
)
DC12 V
RS-485
Rear
8.7. Serial Port

[RS-232C]

Use a null modem cable such as the YR-S2320 when connecting control terminals of the remote controller to

this terminal. No RS-232C connector plug is supplied with the unit.

[RS-485]

Connect the control terminal of the remote controller to this terminal.

• Applicable cable

Solid cable: AWG28 (Ø 0.32 mm) - AWG22 (Ø 0.65 mm)

Stranded cable: AWG28 (0.08 mm2) - AWG22 (0.32 mm2)

Note

Strip the cable sheath approximately 10mm, then insert the cable while pushing down on the terminal button

with a screwdriver.

• RS-232C Connector D-sub 9P

1 2 3 4 5
6 7 8 9
1
2
3
4
5
6
7
8
9
Unconnected
RXD (Reception data)
TXD (Transmission data)
Unconnected
GND
Unconnected
RTS (Transmission request)
CTS (Transmission permission)
Unconnected
Both the RTS and CTS pins are internally shorted.
No. Terminal name