Back Wall of

 

Chase/Enclosure

Outside Wall

Including Finishing

Materials If Any.

 

 

15-1/2"

 

(394mm)

 

37" (940mm)

Figure 4

 

 

Back Wall of

 

Chase/Enclosure

 

Including Finishing

 

Materials If Any.

41"

 

(1041mm)

13-1/2"

 

 

(343mm)

 

29"

 

(737mm)

37" (940mm)

58-1/2" (1486mm)

Figure 5

3"

7"

(76 mm)

(178 mm)

Figure 7

The gas control valve is located in the lower control compartment. To access the valve open the lower control compartment door (Figure 9 ).

The regulator has a 3/8" NPT thread inlet port and is fitted with a 3" (76 mm) long nipple, ³⁄₈" NPT on both ends. Plan the connections ac- cordingly.

We recommend that the gas line be routed for the right side of the appliance to ensure ad- equate access to the rear lower compartment for installation and servicing of the optional FAB-1100 blower.

Control Valve (Standard)

Lower Control

Compartment Door

Figure 9

Secure all joints tightly using appropriate tools and sealing compounds (ensure pro- pane resistant compounds are used in propane applications).

Turn on gas supply and test for gas leaks, using a gas leak test solution (also referred to as bubble leak solution).

Note: Using a soapy water solution (50% dish soap, 50% water) is an effective leak test solution but it is not recommended, because the soap residue that is left on the pipes/ fittings can result in corrosion over time. Never use an open flame to check for leaks.

6

37-1/4" (946 mm)

15-1/2" (394 mm)

37" (940 mm)

Figure 6

Step 2. Route a 1/2" (13 mm) gas line along the left or right side framing (Figure 7 ).

All appliances have a 3" long 3/8" NPT nipple installed at the regulator. To quickly and easily complete the gas line routing, use the gas flex line kit, Model GFLV.

Step 3. Position appliance into prepared fram- ing, secure with 6d nails at the nailing flange along each side.

Step 4. Connecting Gas Line – Make gas line connections. All codes require a shut-off valve mounted in the supply line. Figure 8 illustrates two methods for connecting the gas supply. Installation methods and materials must be in compliance with local codes.

 

Gas Flex Line Kit, Model GFLV

1/2" x 3/8" Flare

3/8" NPT x 3/8"

Flare Fitting

Shut-Off Valve

Gas Valve

 

3/8" Flex Tubing

 

3/8" Nipple, Standard

 

with all Units

Gas Stub

3/8" Union

3/8" Close Nipple

 

 

3/8" Shut-Off Valve

 

1/2" x 3/8" Reducer

Figure 8

 

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

Page 6
Image 6
TOA Electronics VF4000-CMP-2 dimensions With all Units