COUNTERTOP FOODWARMERS

SECTION V

Fusing

This warmer draws 4.0 amps at 120 Volts. Be sure the circuit to which it will be connected is adequately wired and fused to accept this added load.

SECTION VI

A. Preventive Maintenance

Observe well for lime build-up. Remove as necessary. Lime will affect the performance of your unit.

B. Purpose of each electrical component.

ON/OFF Switch - Turn on power to device. Signal light glows to show power is on.

Operating Thermostat - (Thermo Disc Type for 1529), (Infinite Switch for 1523 and 1527) Cycles heating unit on and off to maintain an average temperature of 170 (filled with water level mark in well.)

Heating Unit - Offers heat to bottom of well.

Hi-Temperature Thermostat - (bi-metal type) turns buzzer on when water boils. (1529 Models).

Audible Buzzer - Signals operator to fill well with water immediately.(1529 Models).

TROUBLE SHOOTING INFORMATION

DURING NORMAL OPERATION (WATER IN WELL)

 

Symptom

Possible Cause

 

1.

No Signal Light

No incoming power.

 

 

No Heat

Switch Defective.

 

 

No Buzzer

Wire off.

 

2.

No Signal Light

Switch light defective.

 

 

Heats

 

 

 

 

 

 

 

3.

Signal Light Glows

Wire off.

 

 

No Heat

Heating unit defective.

 

 

 

Operating thermostat defective.

 

 

 

 

 

4.

Signal Light Glows

Hi-temperature thermostat defective.

 

 

Buzzer Sounds

 

 

 

 

ABNORMAL OPERATION (NO WATER IN WELL - EVAPORATED DRY)

 

 

 

 

 

Symptom

Possible Cause

 

1.

Signal Light Glows

Buzzer defective.

 

 

No Buzzer

Hi-Temperature thermostat defective.

 

 

 

 

 