Flow Data Review
1.With the Function dial in the REVIEW position, turn the Lower Line knob to display Flow Data.
REVIEW MODE
Flow Data
2.Turning the Upper Line knob right displays the Flow Data review screens in the following sequence:
• Master Valve Status | • Flow Meter K and Offset Value |
• View Excluded Stations | • Flow Thresholds (GPM) |
• Flow Meter Status/Size | • Flow Delay (Minutes) |
3.All Flow Review screens are self explanitory, with the exception of View Excluded Stations. The initial screen provides a Skip/View option. To review the stations excluded from flow monitoring, turn the Lower Line knob to select View.
VIEW EXCLUDED STATIONS
View (No Flow Only)
4.Turn the Upper Line knob right to display the first 8 stations. Continue turning the knob right to display additional stations.
01 02 03 04 05 06 07 08 N N N N N N Y Y
In the example above, station 7 and 8 are excluded from the flow monitoring function.
39