![](/images/new-backgrounds/1123363/1233635x1.webp)
Arc Adjustment Procedure ________________________________________________________
WARNING
DUE TO THE HIGH OPERATING PRESSURE, NEVER STAND OR LEAN DIRECTLY OVER THE TOP OF THE SPRINKLER OR COME IN CONTACT WITH THE SPRAY. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY.
The 835S and 855S sprinkler models can be operated in
Figure 3
1.Using the sprinkler
2.Find the sprinkler left stop by rotating the turret counter clockwise until it stops. The left stop indicates the fixed stop of the arc. See Figure 4.
3.Check the left stop alignment with the left most area being irrigated. Adjust by ratcheting
the riser clockwise or counterclockwise until the sprinkler left stop points to the correct area. See Figure 5.
CAUTION: The riser can only ratchet when the sprinkler is not operating.
Attempting to ratchet the riser during operation may damage the sprinkler.
The turret can also be used to adjust the left stop. If the left stop falls short of the desired border, rotate the turret counterclockwise until it is aligned with the left watering border. See Figure 4.
If the left stop exceeds the border, rotate the turret clockwise until the right stop. Continue to advance the turret the same distance that the left stop exceeded the border.
See Figure 6.
4.Find the sprinkler right stop by rotating the turret clockwise until it stops. See Figure 6. Note: If the sprinkler is set at 360°
5.Adjust the arc while the turret is pointing at the right stop. Hold the sprinkler riser firmly while pressing the release on the adjustment band. Rotate the turret counterclockwise or clockwise to the desired right stop. See Figure 7.
6.Activate the sprinkler to check proper arc setting and adjust as necessary.
Figure 4 |
Figure 5 |
Figure 6 |
Figure 7 |
3