A

 

B

C

D

E

F

G

H

I

J

1

 

 

 

 

 

 

 

 

 

 

 

2-Breaker

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Customer Supply

 

 

 

 

 

 

 

 

 

Maintenance

 

 

 

 

 

Bypass

 

 

 

 

Bypass

 

 

 

 

 

 

 

Isolation

 

 

 

 

Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Transformer

 

 

 

 

 

 

 

2

 

 

 

 

D

 

Y

 

 

 

 

52C

2

 

 

 

 

 

 

 

 

 

3

 

 

 

UPS Cabinet

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maintenance Bypass

 

 

 

 

 

 

4

 

 

 

Static Switch Bypass

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-Break

 

 

 

 

 

5

Transformer

 

SYNC

 

Make-Before

Transformer

 

 

5

AC Input

Isolation

 

 

 

 

Output

 

AC Output

 

 

 

 

Converter

Inverter

 

 

 

 

 

(208-600V),

D

Y

MCCB

Contactor

Contactor

 

Y

Y

52L

(208-600V)

 

 

 

 

3Ph/4W,

 

3Ph/3W,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50/60Hz,

 

50/60Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15 kVA,

6

6

 

 

 

High

 

High

 

 

 

 

 

 

 

Freq.

 

Freq.

 

 

 

0.8 PF

 

 

 

 

 

Filter

DC Chopper/

Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Charger

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

7

8

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

72B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

ST

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery Cabinet(s) or Rack(s) with DC Breaker

 

 

 

 

 

 

 

 

 

 

 

Customer

 

 

 

 

 

 

 

Customer

 

 

 

10

 

 

 

 

 

 

 

 

10

supplied

 

 

 

 

 

 

 

supplied

 

wiring

 

 

 

 

 

 

 

wiring

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1) This drawing is for illustration purposes only and is subject to change without notice. TIC

DATE 03/25/04

TOSHIBA

4200FA XT2 UPS, 15 kVA Capacity

NOTES

 

 

 

 

 

Drawn by

 

TITLE

One-Line Drawing

 

 

 

 

 

 

 

 

 

EO

 

 

 

 

 

 

is not responsible for any errors or omissions.

 

 

 

 

 

 

INTERNATIONAL CORPORATION

 

Single Input Transformer Model,

 

 

 

 

 

 

 

 

Approved by

 

 

 

2) A Maximum of 2 transformers can be equipped within the standard UPS cabinet.

 

shown with External Bypass Transformer and

 

JIS

Houston Texas, USA

3) An output transformer is not equipped in models with 208/120V output.

DATE 03/25/04

THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF

External 2-Breaker Maintenance Bypass

Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TOSHIBA INTERNATIONAL CORPORATION AND SHALL NOT

DRAWING NO.

REV.

 

 

 

 

 

 

 

 

BE REPRODUCED, USED, OR DISCLOSED TO OTHERS

 

T42X3X150XAMXN

1.2

 

 

 

 

 

 

 

 

 

UNLESS PRIOR WRITTEN AUTHORIZATION IS OBTAINED.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 1
Image 1
Toshiba 4200FA XT2 manual Toshiba, AC Input, AC Output, International Corporation