MEMBRANE SWITCH REMOVAL

1. Remove three M2.5x3 flat head silver screws
securing the membrane switch.
2. Lift out the membrane switch assembly.
FIELD REPLACEABLE UNIT DOCUMENTATION
Tecra
TM
9000 Series
TOSHIBA
Tough Enough for Today’s World.
1. Remove four M2.5x4 brass screws securing the left
and right speakers.
2. Lift out the speakers.

BOTTOM PCB REMOVAL

1. Disconnect the battery harness from PJ18 on the
bottom PCB.
2. Remove five M2.5x4 brass screws securing the bottom
PCB.
3. Lift out the bottom PCB.
Bottom
board
Battery harness
M2.5x4
brass
screws
M2.5x3 silver screws
Membrane
switch assy

SPEAKERS REMOVAL

Left and right
speakers
M2.5x4 brass screws
PJ18