To Charge the Battery Pack

WARNING!

1.The B-EP800-CHG-QM-R battery charger is designed for charging the B-EP802- BT-QM-R/ B-EP804-BT-QM-R lithium-ion battery packs. DO NOT charge any other battery packs, or explosion, combustion, or overheating may result.

2.If the battery charger gives out smoke, a bad smell, or extraordinary heat, immediately unplug the power cord from the AC outlet. Failure to do this may cause fire or electric shock.

Please use the following procedure to charge a battery pack (B-EP802-BT-QM-R/B- EP804-BT-QM-R).

5.Insert the battery pack into the slot in the orientation shown below.

The CHARGE lamp will light up and charging will begin.

NOTE:

Insert an appropriate size of the battery pack according to the partition’s orientation. Failure to do this may damage the battery pack or affect charging operation.

The CHARGE lamp indicates a charging status.

Battery Pack

CHARGE Lamp

Partition

1.Fit the partition into the slot. The orientation of the partition differs depending on the battery pack size (B-EP802-BT-QM-R or B-EP804-BT-QM-R) to be charged.

When charging B-EP802-BT-

When charging B-EP804-BT-QM-R

QM-R battery pack

battery pack

Tab

Tab

NOTE:

Fit the partition in the correct position and orientation and make sure the tabs are fit into the holes.

Be careful not to lose the partition.

Care must be taken not to mistake the orientation, as the partition cannot be removed once it is fitted.

2.Connect the AC adapter to the battery

charger.

Battery Charger

3. Connect the power cord to the AC

 

adapter.

 

4. Connect the power cord to an AC outlet.

Power Cord

AC Adapter

8

NOTES:

1.

Battery packs should be charged on condition that both ambient temperature and

 

battery temperature fall within a range of 0 °C to 40°C.

2.

The battery charger will get warmer during charging (room temperature + about

 

30°C). This is not abnormal.

3.

If the over discharge protector has been operated on a battery pack, the

 

CHARGE lamp may not light for a while. Leave the battery charger and the battery

CHARGE lamp

State

 

OFF

Unconnected.

NOTE:

Red

Charged.

The green light does not go off until the

Green

Completed.

battery pack is removed from the slot.

Blinking red

Abnormal state

 

6.After charging is completed, remove the battery pack from the battery charger.

7.Disconnect the power cord from the AC outlet.

Charging time

To charge an empty battery pack:

Battery pack

Charging time

B-EP802-BT-QM-R

about 3 hours

 

(Until the min. of 85% of the nominal capacity is charged.)

B-EP804-BT-QM-R

about 3 hours

 

(Until the min. of 85% of the nominal capacity is charged.)

•Charging time may differ depending on the condition of the battery pack or the operating temperature.

•After the CHARGE lamp turns from red to green, the battery charger may continue to charge the battery pack for up to one more hour until the full charge level (95% or more).

9

TROUBLESHOOTING

If you have any problems while using this product, please check the following point first.

If a problem cannot be solved by taking actions described below, unplug the battery charger and contact the dealer or an authorised TOSHIBA TEC service representative for assistance.

pack alone for a few minutes. Stop using the battery pack if the CHARGE lamp

does not light at all as the battery pack may be faulty.

4. The battery pack can be removed from the battery charger while charging is in

progress. However, the battery lasting time depends on the charging time.

5. After the charging is completed, do not leave the battery pack in the charger too

long. The battery pack gradually discharges.

6. Periodically clean the charger terminals with a soft dry cloth.

Symptom

A battery pack is loaded in the battery charger, but the CHARGE lamp does not light up in red.

The CHARGE lamp blinks in red.

Charging time overruns the approximate specified time.

Battery pack does not last long time though the battery is fully charged.

The battery pack cannot be inserted into the slot.

Cause and resolution

The power cord is not connected properly. Firmly connect the power cord to the AC

adapter and the AC outlet.

The terminals of the battery charger or the battery electrodes are stained.

Wipe clean those portions with a soft dry cloth.

You are attempting to charge a battery pack with the over discharge protection activated (The CHARGE lamp may not light up immediately after loading a battery.)

Leave the battery charger and the battery pack alone for a few minutes. If the CHARGE lamp does not light after all, stop using the battery pack, as the battery pack may be faulty.

The partition is not fitted.

Fit the partition in the correct orientation.

A battery pack failure is detected.

It could be the end of battery life. Replace the battery pack with a new one.

Charging time varies depending on the condition of the battery pack, ambient temperature, etc.

If the battery charger continues charging even after the specified time has passed, stop charging and replace the battery pack with a new one.

It could be the end of battery life.

Replace the battery pack with a new one.

The partition is not set completely. Fit the partition completely.

10

11

Page 3
Image 3
Toshiba B-EP800-CHG-QM-R owner manual To Charge the Battery Pack, Symptom, Cause and resolution