PROGRAMMING PROCEDURES-INTRODUCTION SECTION 100-816-301 MARCH 1993 TABLE 1 -E PROGRAM 03 SLOT ASSIGNMENTS
Press...
Step BUHONS

+ LED keys

(DK16 ONLY) #
Action description LCD RESPONSE . . .
1. Use an LCD digital or electronic telephone with a NO. OF STATION (10 - 29)
programming template. JAN 20 SUN 06:43
2. *.#*#1*2*3 PROGRAM MODE
Enter programming mode.
3. SPKR 0 3 HOLD PROGRAM = 03
Access Program 03. After SPKR key is pressed, system DATA STORE
beeps to indicate program number may be entered.
4. SPKR 03 SELECT =
Prepare system for a selection.
5. Enter a PCB slot number (00-07). 03 SELECT = (00 - 07)
CARD = Default code will
The system defaults as follows: appear here
00 03 SELECT = 00
Initialized data assigns CTU slot 00 to be non-optioned, CARD = 91 -SLOT NUMBER
without a K4RCU.
01 03 SELECT = 01
Initialized data assigns DKU slot 01 to be non-optioned CARD = 61 -SLOT NUMBER
without a door phone or DDSS console.
02 03 SELECT = 02
Initialized data assigns fixed KCOU slot 02 with code Il. CARD = 11 -SLOT NUMBER
03 03 SELECT = 03
Initialized data assigns fixed KSTU slot 03 with code 31. CARD = 31 -SLOT NUMBER
04-07 03 SELECT = 04 - 07.
Initialized data assigns Expansion Unit’s universal slots CARD = 00 LSLOT NUMBER
04 - 07 to be empty, code 00.
6. 00-92 03 SELECT = (00 - 07)
Dial the PCB code recorded on the record sheet. CARD = (00 - 92)
Refer to the PCB code reference table on Program 03
System Record Sheet for a definition of the codes.
7. HOLD 03 SELECT = (00 - 07)
Secure data in system programming. DATA PROGRAMMED
8. SPKR 03 SELECT =
Prepare system for another selection (go back to
step 5), or exit Program 03 (continue with step 9).
9. # # HOLD 03 SELECT = ##
Secure Program 03 data in system memory. DATA PROGRAMMED
10. SPKR PROGRAM =
Exit Program 03. Enter another program number, or exit
programming mode (go to step 11).
System beeps to indicate it’s exiting Program 03.
11. # # HOLD NO. OF STATION (10 - 29)
Exit programming mode. JAN 20 SUN 06:58
12.

In order to secure Program 03 entries, POWER OFF

for 5 seconds, then POWER ON.

l-11