Handset Level AdjustmentsChange the Carbon setting if a Carbon type handset or headset is connected to the
handset jack.
To change the Carbon Setting
1. Press 3+6+9+Hold (simultaneously).
2. Press 0.
3. Press FB6 to toggle On/Off.
FB, LED On: Carbon type handset
FB, LED Off: IP5000 ECM handset (default)
4. Press Hold to set the option.
5. Go off-hook, then on-hook to exit the program mode.
To adjust the Handset Transmit Level for IP5000-series telephones
1. Press 3+6+9+Hold (simultaneously).
2. Press Redial.
3. Press Hold.
FB1: 6~8 [db] (default 0 [db])
4. Press Hold to set the option.
5. Go Off-hook, then on-hook to exit the program mode.