Reliability
MTBF
Power ON Hours
ON/OFF Cycles
Number of Access
Operating Duty Cycle
MTTR
Environmental
Ambient Temperature
Operating
Storage
Shipping
Temperature Gradient
Operating
Storage/Shipping
Relative Humidity
Operating
Storage/Shipping
Vibration
Operating (5 to 500 Hz) (read) Operating (5 to 500Hz) (write)
Transporting
Shock
Acoustical Noise
Power
DC Voltage and Current Requirements
Physical
Height
Width
Depth
Weight
Connectors
IDE Interface Connector
9
100,000 hours
5,436 hours/year
313cycles/year 600,000 accesses/year
20% of Power ON time (Reading/Seeking)
2% of Power ON time (Writing/Seeking)
0.5 hours
5º to 50º C (41º to 122º F)
11º C /hour (max)
20º C /hour (max)
8% to 80%
5% to 95% (wet bulb 40 C max)
2.45m/s2 (0.25G)
2.45m/s2 (0.25G)
9.8m/s2 (1.0G)
9.8m/s2 (1.0G)
490m/s2 [50G] 40dB
+5V ±5% (Operating)
0.5" (12.7mm) 5.04" (128mm) 4.96" (126.1mm) 7.05oz (.2kg)
50 Pin I/F ATAPI Standard