General
A-weighted Sound Power Level [dB(A)]

General

Data

Product Specifications

Model No. 1

4TTX5018A1

4TTX5024A1

4TTX5030A1

4TTX5036A1

Electrical Data V/Ph/Hz 2

200/230/1/60

200/230/1/60

200/230/1/60

208/230/1/60

Min Cir Ampacity

8

11

15

22

Max Fuse Size (Amps)

15

20

25

35

Compressor

CLIMATUFF®

CLIMATUFF®

CLIMATUFF®

CLIMATUFF® - SCROLL

No. Used - No Stages

1-1

1-1

1-1

1-1

RL Amps - LR Amps

6.2 - 38.6

8.6 - 57.8

11.1 - 63

16.7 - 79

Outdoor Fan FL Amps

0.74

0.74

0.74

0.93

Fan HP

1/8

1/8

1/8

1/5

Fan Dia (inches)

27.6

27.6

27.6

26.6

Coil

Spine Fin™

Spine Fin™

Spine Fin™

Spine Fin™

Refrigerant R-410A

6/09-LB/OZ

6/10-LB/OZ

6/10-LB/OZ

7/11-LB/OZ

Line Size - (in.) O.D. Gas 3

1/2

5/8

3/4

3/4

Line Size - (in.) O.D. Liquid 3

3/8

3/8

3/8

3/8

Dimensions H x W x D (Crated)

45.4 x 35.1 x 38.7

45.4 x 35.1 x 38.7

45.4 x 35.1 x 38.7

53.4 x 35.1 x 38.7

Weight - Shipping

271

275

276

283

Weight - Net

227

230

232

235

Start Components

YES

YES

YES

NO

Sound Enclosure

YES

YES

YES

YES

Compressor Sump Heat

NO

NO

NO

NO

Optional Accessories: 4

 

 

 

 

Anti-short Cycle Timer

TAYASCT501A

TAYASCT501A

TAYASCT501A

TAYASCT501A

Evaporator Defrost Control A/C

AY28X079

AY28X079

AY28X079

AY28X079

Rubber Isolator Kit

BAYISLT101

BAYISLT101

BAYISLT101

BAYISLT101

Crank Case Heater Kit

BAYCCHT300

BAYCCHT300

BAYCCHT300

BAYCCHT301

Hard Start Kit Scroll

 

 

 

BAYKSKT260

Extreme Condition Mounting Kit

BAYECMT001

BAYECMT001

BAYECMT001

BAYECMT001

Snow Leg - Base & Cap 4" High

BAYLEGS002

BAYLEGS002

BAYLEGS002

BAYLEGS002

Snow Leg - 4" Extension

BAYLEGS003

BAYLEGS003

BAYLEGS003

BAYLEGS003

Seacoast Kit

BAYSEAC001

BAYSEAC001

BAYSEAC001

BAYSEAC001

Refrigerant Lineset 5

TAYREFLN850

TAYREFLN950

TAYREFLN7*

TAYREFLN7*

1Certified in accordance with the Unitary Air-Conditioner equipment certification program which is based on AHRI Standard 210/240.

2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.

3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line.

For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. (denotes latest revision)

4 For accessory description and usage, see page 5.

5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.

MODEL

SOUND POWER

A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)] High Stage

 

LEVEL [dB(A)]

63

125

250

500

1000

2000

4000

8000

 

 

 

4TTX5018A1

73

51

58

65.3

68.2

64.5

66.4

59

51.6

 

 

 

 

 

 

 

 

 

 

 

 

4TTX5024A1

74

51.5

59.6

64.3

71.5

70.5

64.8

58.6

52.8

 

 

 

 

 

 

 

 

 

 

 

 

4TTX5030A1

73

54.8

62.8

64.1

68.2

67.1

65.7

60.1

54.1

 

 

 

 

 

 

 

 

 

 

 

 

4TTX5036A1

72

53.7

58.9

62.1

66.8

66.8

61.2

58.8

45.4

 

4TTX5042A1

73

52

55.7

57.8

67.2

69.2

65

59.5

48.3

 

 

 

 

 

 

 

 

 

 

 

 

4TTX5048A1

73

52.1

55.9

68.3

67.1

65.4

62.2

58.6

48.8

 

 

 

 

 

 

 

 

 

 

 

 

4TTX5049E

72

43.8

53.6

56.8

60.9

61.9

57.2

50.4

40.7

 

4TTX5060A1

74

52.4

54.9

62.1

66.5

71.4

67.2

60.9

49.6

 

 

 

 

 

 

 

 

 

 

 

 

4TTX5061E

73

41.8

53.8

58

64.3

64.2

57.5

54

47.1

 

 

 

 

 

 

 

 

 

 

 

 

Note: Rated in

accordance with AHRI

Standard 270-2008.