Trane 4TWB4 manual General Data, Product Specifications, Model No, Min Cir Ampacity

Models: 4TWB4

1 16
Download 16 pages 32.21 Kb
Page 5
Image 5
Manual background

General

Data

Product Specifications

Model No. 1

4TWB4042E1

4TWB4048E1

4TWB4049E1

4TWB4060E1

4TWB4061E1

Electrical Data V/Ph/Hz 2

208/230/1/60

208/230/1/60

208/230/1/60

208/230/1/60

208/230/1/60

Min Cir Ampacity

27

29

28

35

36

Max Fuse Size (Amps)

45

50

50

60

60

Compressors

CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL

CLIMATUFF® - SCROL

CLIMATUFF® - SCROLL CLIMATUFF® - SCROL

RL AMPS - LR AMPS

19.9 - 109

21.8 - 117

21.8 - 117

26.4 - 134

26.4 - 134

Outdoor Fan FL Amps

0.93

0.93

1.00

0.93

2.80

Fan HP

1/5

1/5

1/5

1/5

1/3

Fan Dia (inches)

27.6

27.6

27.6

27.6

27.6

Coil

Spine Fin™

Spine Fin™

Spine Fin™

Spine Fin™

Spine Fin™

Refrigerant R-410A

12/1-LB/OZ

13/9-LB/OZ

13/10-LB/OZ

12/1-LB/OZ

13/12-LB/OZ

Line Size - (in.) O.D. Gas 3

3/4

7/8

7/8

7/8

1-1/8

Line Size - (in.) O.D. Liquid 3

3/8

3/8

3/8

3/8

3/8

Dimensions H x W x D (Crated)

46.4 x 35.1 x 38.7

51 x 35.1 x 38.7

51 x 35.1 x 38.7

51 x 35.1 x 38.7

51 x 35.1 x 38.7

Weight - Shipping

313

331

331

332

332

Weight - Net

277

294

294

295

295

Start Components

NO

NO

NO

YES

YES

Sound Enclosure

NO

NO

NO

NO

NO

Compressor Sump Heat

YES

YES

YES

YES

YES

Optional Accessories: 4

 

 

 

 

 

Anti-short Cycle Timer

TAYASCT501A

TAYASCT501A

TAYASCT501A

TAYASCT501A

TAYASCT501A

Evaporator Defrost Control A/C

AY28X084

AY28X084

AY28X084

AY28X084

AY28X084

Rubber Isolator Kit

BAYISLT101

BAYISLT101

BAYISLT101

BAYISLT101

BAYISLT101

Hard Start Kit Scroll

BAYKSKT260

BAYKSKT260

BAYKSKT260

 

 

Extreme Condition Mounting Kit

BAYECMT004

BAYECMT004

BAYECMT004

BAYECMT004

BAYECMT004

Snow Leg - Base & Cap 4" High

BAYLEGS002

BAYLEGS002

BAYLEGS002

BAYLEGS002

BAYLEGS002

Snow Leg - 4" Extension

BAYLEGS003

BAYLEGS003

BAYLEGS003

BAYLEGS003

BAYLEGS003

Seacoast Kit

BAYSEAC001

BAYSEAC001

BAYSEAC001

BAYSEAC001

BAYSEAC001

Refrigerant Lineset 5

TAYREFLN7*

TAYREFLN3*

TAYREFLN3*

TAYREFLN3*

TAYREFLN3*

 

 

 

 

 

 

1Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.

2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.

3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line.

For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. (denotes latest revision)

4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.

22-1834-09

5

Page 5
Image 5
Trane 4TWB4 manual General Data, Product Specifications, Model No, Min Cir Ampacity, Optional Accessories