Manuals
/
Brands
/
Household Appliance
/
Furnace
/
Trane
/
Household Appliance
/
Furnace
Trane
GHND-SVX01A-EN manual
1
1
56
56
Download
56 pages, 3.75 Mb
Installation Oper
ation
Maint
enance
July 2007
GHND-S
VX0
1A
-EN
GHND
GHPD
High Ef
ficienc
y Pr
opeller
F
an Gas Unit Heat
er
Contents
Main
Preface and Warnings and Cautions
Contents
Model Number Description
Model Number Description
Description
General Information
General Safety Information
General Safety Information
Hazardous Service Procedures!
Altering Unit!
Hazardous Voltage and Gas!
General Information
General Safety Information
Ground Wire!
Flammable Vapors!
Note 1. Ratings shown are for unit installations
Page
Installation
Page
Page
Clearances:
Page
Flammable Vapors!
Pipe Sizing
Hazard of Explosion and Fire!
Gas Supply Piping
Gas Pipe Size
Table 3.
Gas Supply Piping
Pipe Installation
Pipe Installation
Hazard of Explosion of Fire!
Hazard of Explosion!
Pipe Installation
Electrical Connections
Hazardous Voltage!
Ground Wire!
Thermostat Wiring and Location
Electrical Connections
Thermostat wiring and location
THERMOSTAT HEAT ANTICIPATOR ADJUSTMENTS:
FAN TIME DELAY CONTROL
Carbon Monoxide Poisoning!
Venting for Power Vented Unit Heaters
Page
Equipment Damage!
Carbon Monoxide Poisoning!
Page
Page
Page
Operation
POWER VENTED PROPELLER UNITS INTERMITTENT (SPARK) PILOT IGNITION
Page
Page
Gas Input Rate
GAS INPUT RATE
Gas Pressure Adjustments
Table 6. Main burner orifice schedule
PRIMARY AIR SHUTTER ADJUSTMENT
PILOT ADJUSTMENT
MANIFOLD PRESSURE ADJUSTMENT
Maintenance
Hazardous Service Procedures!
Periodic Service
Combustible Materials!
Hazardous Voltage and Gas!
Trouble Shooting
Trouble Shooting Guide:
A. Flame lifting from burner ports.
B. Flame pops back.
C. Noisy flame.
D. Yellow tip flame (some yellow tipping on propane gas is permissible).
E. Floating flame.
F. Gas Odor.
G. Delayed ignition.
H. Failure to Ignite.
J. Condensation of water vapor.
K. Burner won't turn off.
L. Rapid burner cycling.
Page
P. Fan motor turns on and off while burner is operating.
Q. Fan motor will not stop.
R. Not enough heat.
T. Too much heat.
U. Cold air is delivered on start up.
V. Cold air is delivered during heater operation.
W. No Spark.
X. Spark present but pilot does not light.
Y. Pilot lights Main valve does not energize.
Z. Hi-Limit switch tripping.
AA. Noisy power venter.
BB. Power venter will not run.
CC. Power venter motor turns on and off while burner is operating.
DD. Power ventor motor will not stop.
Part Identification
Page
Figure 24. Power vent assembly
Part Identification
Installation of Power Vented Motor
INSTALLATION INSTRUCTIONS FOR FIELD REPLACEMENT OF POWER VENTER MOTOR
Hazardous Voltage and Gas!
Page
Gas Equipment Start-Up
PRE-INSPECTION INFORMATION
GENERAL (with power and gas off)
Gas Equipment Start-Up
BLOWER (with power on and gas off)
Remarks:
GAS HEATING (with power and gas on)