Index
62 CNT-APG002-EN
®
enable conditions, 24, 25, 27
error
and the velocity model, 7
and throttling range, 9-10
definition, 2
error deadband, 19-21
and sensor resolution, 20
and staging, 20-21, 37
calculating for staged outputs,
21, 40
for modulating outputs, 20
recommended values, 19
execution frequency, see sampling
frequency
Ffail-safe conditions, 24, 25, 27
failure conditions, 24, 27, 34
fans, staging, 37-44
See also staging
formulas, mathematical, 55
frequency, see sampling frequency
Ggains, 10-11
4 to 1 ratio, 11, 52
calculating, 11
derivative, 3, 6, 10-11, 52
integral, 3, 7, 10-11
proportional, 7, 10-11
recommended values, 11
troubleshooting, 45, 46, 50
graphing PID output, 45, 52
Hheating, 16, 17
high setpoint limit, 36
hot water valve
PCL program, 29
TGP program, 30
troubleshooting, 47-50
hysteresis, 42
IIF statement in PCL, 24
integral
control, 4-5
gain, 3, 7, 10-11
windup, 5, 7
LLimit block in TGP, 27
low setpoint limit, 36
Mmathematical formulas for PID
control, 55
MAX operator in PCL, 24-25
measured variable, 2
MIN operator in PCL, 24-25
minimum-on and -off times, 20, 42
modulating outputs, 20
OOr block in TGP, 39
oscillating output, 13, 31, 51
output
at maximum, 45, 46, 51
at minimum, 45, 46, 51
control of actuator, 2
graphing, 45, 52
of PID loop, 2
oscillating, 13, 31, 51
overshoot, 1, 46
undershoot, 46
overshoot, 1, 46
PPCL, see process control language
PID block in TGP, 26
PID control
definition, 1
mathematical formulas for, 55
overview, 1-2
PID calculations, 3-6
See also derivative control,
integral control, proportional
control
PID Properties dialog box in TGP, 26
pressure control
building, 18, 32-33
duct static, 11, 12, 18
process control language, 23-25
cascade control program, 34
DDC function, 23
DDC Loop Parameter screen, 24
example of PCL program, 25
hot water valve program, 29
IF statement, 24
MAX operator, 24-25
MIN operator, 24-25
relief damper program, 32
staging program, 38
process variable, 2
programming, 23-27
cascade control program, 34, 35
disable conditions, 24, 25, 27
enable conditions, 24, 25, 27
fail-safe conditions, 24, 25, 27
failure conditions, 24, 27, 34
hot water valve program, 29, 30
IF statement, 24
Limit block in TGP, 27
MAX operator, 24-25
MIN operator, 24-25
Or block in TGP, 39
PCL, 23-25
PID block in TGP, 26
PID Properties dialog box in
TGP, 26
relief damper program, 32
staging program, 38
TGP, 26-27
proportional
bias, 3, 40
control, 3, 37, 52, 55
gain, 7, 10-11
Rrecommended values, 9-21
action, 18
error deadband, 19
gains, 11
sampling frequency, 14, 53
relief damper, 32-33
PCL program, 32
TGP program, 32
resolution, sensor, 20, 32
reverse action, 17, 52
routine, see programming