Trane XB200 manual Trouble Shooting, Troubleshooting

Models: XB200

1 24
Download 24 pages 52.82 Kb
Page 18
Image 18

Trouble

-shooting

Page - 18

Pub. No. 22-5204-01

Table 2

Troubleshooting

 

 

 

Symptom

Possible Cause

Action

 

 

 

 

1. Blown fuse or tripped circuit breaker.

1. Replace fuse or reset breaker.

Display will not come on.

2. Furnace power switch OFF.

2. Turn switch to ON.

3. Furnace blower compartment door or panel

3. Replace door panel in proper position to engage safety interlock or

 

 

loose or not properly installed.

door switch.

 

 

 

Temperature display is incorrect.

Temperature display needs calibration.

Calibrate Sensor - User Setup Step 49.

 

 

 

Cannot set Heating setpoint

Deadband between Heating and Cooling set to high

Decrease Deadband setting - User Setup Step 42.

above 80 degrees

 

 

 

 

 

"Service" Flashing on and off.

Control EEPROM write error.

Press any key and Check / Re-enter Setup Choices.

 

 

 

"Service" solid on and "--" in

Indoor temperature sensor open or shorted

Replace Control

temperature display.

 

 

 

 

 

 

1. Upper and/or lower temperature limits were

1. Check the temperature setpoints:

Temperature setting will not

reached.

Heating limits are 40 - 85F.

change. (Example: Cannot set

 

Cooling limits are 65 - 90F.

heating higher or cooling lower).

2. "Keypad locked" is displayed on LCD.

2. Unlock keypad - press Up+Down arrow together until icon disappears.

 

 

 